Service functions and error messages
Page 140
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
Error message Meaning of the error message Measures
Main
index
Sub
index
3
Corrupted data structure in
encoder parameter set
If necessary, determine the data once more and
save it into the encoder again.
4
EEPROM data: Erroneous
customer specific configuration
Motor repaired: perform a homing run and save
to the angle encoder, and then save to the basic
device.
Motor replaced: parameterise the basic device,
perform a homing run, save to the angle encoder
and then save to the basic device.
7
Write protected EEPROM angle
encoder
Please contact the Technical Support.
9
EEPROM angle encoder too
small
10
0
Overspeed
(motor overspeed protection)
Encoder offset angle correct?
Overspeed protection limit too small?
11
0
Error at start of homing run
No servo drive enabling.
1
Error during homing run
Homing has been interrupted for example by
disabling the servo drive.
2
Homing run:
No valid index pulse
The required index pulse is missing.
3
Homing run: timeout
The maximum time parameterized for homing
has been consummated before the homing run
has been completed. Please check the time
parameterisation.
4
Homing run :
Wrong or invalid limit switch
The associated limit switch is not connected.
Limit switches mixed up?
Move the limit switch so that it is not located in
the area of the index pulse.
5
Homing run:
I²t / following error
Unsuitable parameterisation of acceleration
ramps.
Invalid stop reached, for example because no
homing switch is connected.
Check the connection of a home switch.
Contact the Technical Support.