Functional safety technology
Page 74
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
6.2.4
Application examples
6.2.4.1 Emergency stop circuit:
Inputs
Outputs
PLC
+24 V
+24V
+24 V
0 V
Driver supply of
output stage
0 V
[X3] SAFE STANDSTILL / SUPPLY 24 V
[X1] I/O communication
Mains input
24 V Input
µP
1
2
3
4
5
6
Triggering of relay
ERR (not used)
NC1
NC2
C
ont
rol
ler
enabl
ing
O
ut
put
s
tage
dr
iv
er
s
uppl
y
Power
contactor
L1
L2
L3
DIN5: Controller enabling
DIN4: Output stage enabling
ARS 2320 -
ARS 2360W
K1
EMERGENCY
STOP request
EMERGENCY STOP
requested
21
9
1
2
3
F
eedbac
k
dr
iv
er
s
uppl
y
O
ut
put
s
tage enabl
ing
[X9.] Power supply
safety switching
device
EN ISO 13849-1,
Category 3
Performance Level d
Drawn contact
position:
EMERGENCY
STOP requested
or supply voltage
switched off
Figure 13:
Emergency-off circuit in accordance with EN ISO 13849-1, Category 3
Performance Level d, and stop category 0 in accordance with 60204-1.
Содержание ARS 2320
Страница 1: ......