Service functions and error messages
Page 143
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
Error message Meaning of the error message Measures
Main
index
Sub
index
2
Initialization error
3
Unexpected state
17
0
Max. following error exceeded
Increase error window.
Acceleration parameterization too large.
1
Encoder difference control
Check the connection of the encoders.
Check the parameterized gear.
18
0
Warning level analogue motor
temperature
Motor too hot? Check the parameterization
(current controller, current limitation).
Suitable sensor?
Sensor defective?
Check the parameterisation of the sensor and
sensor characteristic.
Error also occurs if sensor is bypassed: device
defective. Please, send the servo drive to our
sales partner.
21
0
Error 1 current measurement V Please contact the Technical Support.
1
Error 2 current measurement U
2
Error 2 current measurement V
3
Error 1 current measurement V
22
0
PROFIBUS:
Wrong initialization
Technology module defective?
Replace the technology module.
Contact the Technical Support
1
PROFIBUS: reserved
Please contact the Technical Support.
2
PROFIBUS:
Communication error
Check the slave address.
Check the bus terminators.
Check the cabling.
3
PROFIBUS:
Invalid slave address
Incorrect slave address. Please select another
slave address.
Содержание ARS 2320
Страница 1: ......