Radiance 10/100 Mbps Services Line Card
66
Event to be triggered. The threshold range is 1 to
900. Example: if window = 100 and threshold = 5,
then if 5 frame errors occur within a window of 10
seconds, an Event Notification OAMPDU will be
generated with an Errored Frame Seconds Summary
Event TLV indicating the threshold has been
crossed.
notify – Enable or disable notification to the specified port’s
OAM peer that the Errored Frame Seconds
Summary Event has been triggered.
Example
:
Console> set oamerrframesecs 1 window 100 threshold 5
Console>
set
oamerrsymperiod
Description
: Set the OAM event attributes for number of errored
symbols detected for a set symbol count window for the
specified port, and enable or disable notification.
Note: This R821 currently does not support this command.
Syntax
:
set oamerrsymperiod <port number> [window <# of
symbols>] [threshold <symbol period threshold>] [notify
<enable | disable>]
Parameters
: port number – the actual port number.
window – Number of symbols over which the threshold is
defined. The range is 125000000 to 3205032704.
threshold – The number of symbol errors that must occur
for the Errored Symbol Period Event to be triggered.
Example: If window = 125000000 and threshold =
20, then if 20 symbol errors occur within 125000000
symbols, an Event Notification OAMPDU will be
generated with an Errored Symbol Period Event TLV
indicating that the threshold has been crossed.
notify – Enable or disable notification to the specified port’s
OAM peer that the Errored Symbol Period Event has
been triggered.
Example
:
Console> set oamerrsymperiod 1 window 125000000 threshold
20
Console>
set
oamloopback
Description
: Start or stop remote loopback on the specified port with
the remote OAM port.
Syntax
:
set oamloopback <port number> [status <start | end>]
[commands <ignore | process>]
Parameters
: port number – the actual port number.
status – initiate or terminate remote loopback with the
remote port. Starting remote loopback causes the
specified port to send a loopback request (with the
loopback enable flags set) to the remote port. Ending