Radiance 10/100 Mbps Services Line Card
120
Error: Trap
destination table is
full.
Up to four trap destinations can be configured. To add a new trap desti-
nation, you must first delete one of the current entries from the table.
Error: Trunk port
must be tagged.
When configuring user VLANs, only the access port can be untagged.
Untagging is not allowed on the trunk port.
Error: Unknown IP
address.
The IP address specified for setting a trap control must be one that is in
the trap destination table. Use the ‘show trapdestinations’ command to
see what IP addresses are available.
Error: Username
cannot be longer
than 32 characters.
The SNMPv3 username must not contain more than 32 characters.
Error: Username
must be have an end
quote.
Multi-word strings require quotation marks at the beginning and end.
Your username entry only has a quotation mark at the start of the string.
Error: Username
must be specified for
SNMPv3 traps.
When configuring an SNMPv3 trap destination, the username parameter
is required for security.
Error: Valid count
values are between 1
and 100.
The maximum number of times the device should attempt to ping a
network host is not in the acceptable range of 1 to 100.
Error: Valid delay
values are between 0
and 10.
The maximum number of seconds the device should wait between
attempt to ping a network host is not in the acceptable range of 0 to 10
seconds.
Error: Valid image
number values are
between 1 and 2.
A value other than ‘1’ or ‘2’ was entered for the OS image number.
Error: Valid image
values are between 1
and 2.
A value other than ‘1’ or ‘2’ was entered for the FPGA image number.
Error: Valid index
number values are
between 1 and 17.
The trap index must be a number between 1 and 17.