105
User Guide
RADIUS Reset
If RADIUS authentication is enabled and the RADIUS server information
is entered incorrectly, a user will not be able to log in due to the bad
configuration. To work around this condition, toggle DIP switch #5 to
clear the RADIUS authentication state. (All other RADIUS settings will be
unaffected.) This will allow the user to log in using the currently
configured user names and passwords.
Technical Specifications
Data Rate
Data Rate ________________________________ 10/100Mbps (Port 1)
__________________________________ 100 Mbps (Port 2)
Power
Input __________________________________ 5 V DC @1.0 A, 5.0 W
Environmental
Operating Temperature ______________________________0° to 50° C
Storage Temperature _____________________________ -25° to 70° C
Operating Humidity ___________________ 5% to 95% non-condensing
Weight_______________________________________ 3.2 oz (0.09 kg)
Network Connections
Twisted-Pair Interface
Connector ___________________________ Shielded RJ-45, 8-pin jack
Impedance _________________________________100 ohms nominal
Supported Link Length _________________________________ 100 m
Signal Level Output (peak differential) _________2.2 to 2.8 V (10 Mbps)
______0.95 to 1.05 V (100 Mbps)
Signal Level Input (minimum) ___________________585 mV (10 Mbps)
__________________200 mV (100 Mbps)
Cable Type ______________________ CAT 3, 4, 5 UTP/STP (10 Mbps)
____________________ CAT 5 or 5E UTP/STP (100 Mbps)
(For NEBS Level III and EN55024:1998 compliance, use only
CAT 5E STP cables.)