59
CLI Commands
reset
Description
: Reset, or reboot, the device and optionally set operational
parameters to factory defaults.
Syntax
:
reset [default]
Parameters
: default – factory default settings.
Example
:
Console> reset default
run config
Description
: Run the saved configuration script. (Refer to “download”
on page 57 for information on downloading a script.) A
script is a text file consisting of CLI commands separated
by carriage returns. There is also an “echo” command that
can be used to print comments to the screen while the
script is running.
Syntax
:
run config <image number>
Parameters
: image number – image number of the configuration script.
Valid numbers are 1 and 2.
Example
:
Configuration script:
echo Setting IP information.
set ip 192.168.1.1 mask 255.255.0.0
echo Disabling management on Port 2.
set port 2 management disable
echo Setting up VLAN information.
set mgmtvlan 101
set uservlan 167 port 1 2
set uservlan 190 port 1 2
set uservlan 233 port 1 2
Console> run config 1
Setting IP information.
Disabling management on Port 2.
Setting up VLAN information.
Console>