MI 3325 MultiServicerXD
193
2
nd
label is intended to mark supply cords.
Data not available will not be printed on the label.
Test or Retest date: is set in the General Settings => Devices => Writing devices menu.
If Auto Sequence
® was modified, its short code is marked with asterisk (*).
Following table describes data content written on RFID / NFC tag.
RFID / NFC tag type
Data
NTAG216
Test code, appliance ID, appliance name, test date, test period,
location, user, status, measurement results.
Note:
Applicable only for PAT measurements. Limited functionality for non PAT data.
C.2
Generic tag format
It is intended for tagging structure objects (element, appliance, equipment), which could be
tested and their location under parent structure object is important. Label printing can be started
from selected structure object (element, appliance, equipment), even if no Auto Sequence
® is
associated with it, or from finished Auto Sequence
® saved under it.
Tag data presented in text area are:
Parent structure object ID (name) (
← Object_name)
Auto Sequence
® short test code (if printing from Auto Sequence®; if printing from object
field is omitted)
Object ID (name)
Test date (
|→ DD.MM.YYYY) or Retest date (→| DD.MM.YYYY), which one is selected
in General Settings => Devices => Writing devices menu
Status (printing from object: overall status of all tests appended to the object or sub-
structure objects; printing from Auto Sequence
®: its status)
User name (Printing from Auto Sequence: user who performed test; printing from object:
current signed-in user)
Tag data presented in machine-readable area are:
Parent structure object ID (name)
Auto Sequence
® short test code (if printing from Auto Sequence®; if printing from object
field is omitted)
Object ID (name)
Test date
Test period (from appliance description)
Auto Sequence
® status (field is omitted, if not printing from Auto Sequence®)
Object status (overall status of all tests appended to the object or sub-structure objects)
User name (Printing from Auto Sequence
®: user who performed test; printing from
object: current signed-in user)
Following table describes tag content arrangement and its data for supported label form size.
Form size
W x H
(mm)
Tag content
arrangement
Data
50 x 25.5
Text
Parent object name, Test code, Object ID, test or retest
date, status, user
QR
Parent object name, Test code, Object ID, test date, test
period, Auto Sequence
® status, Object status, user.