261 of 271
Step Action
Result
Next Step/Solution
7
Conduct a Servo Motor
Resistance Test to check the
resistance of the windings on
the motor servicing the circuit
with the error
Ohms measure near zero or
inconsistent with other phases.
Replace the motor
Resistance is within
specifications
Go to Step 8
8
Problem is caused by some-
thing in the circuitry of the
main controller PCB
You will probably need to re-
place the main controller PCB
Contact Technical Support and
discuss the problem with them.