228 of 271
a. The black (common) electrode of the voltage meter goes on the ground (black wire) terminal,
and the red (positive or hot) electrode of the voltage meter goes on the positive (red wire)
terminal.
b. Measure the DC output voltages. The range should be between 34.5 to 38 DC volts. If the
voltages are not in this range, then replace the power supply assembly.
16. If the green LED on the side of the power supply unit is illuminated and the 36V DC output is be-
tween 34.5 to 38V DC then the power supply assembly is good. Follow the power supply installa-
tion procedures entitled “Power Supply Assembly” to install the Power Supply Assembly into the
machine.
17. If none of the above indicates a failure, the power supply assembly is good and can be installed
in the machine using the procedures for installing the power supply assembly in the section titled
“Power Supply Assembly”.
Table of Contents
Содержание Bravo
Страница 1: ...Technical Manual Rev 082115 ...