18. Using the micro-step command on the keypad, increase (press the Trace key and the Arrow Down
key the angular position back to the lowest needle position. After the needle stops moving, note
the angular position and continue to micro-step in the same direction for at least 1.5 ° more; the
needle should not move.
19. Verify that the dial indicator is zeroed. If it is not on zero, reset the dial indicator to zero.
20. Increase the angular position by micro-stepping until the dial indicator registers a needle bar rise
of 0.001”. Record the angular readout at this height and include all decimal places (
ϴ
).
21. Important: Add 177.5 ° to the angle from the previous step (
ϴ
+177.5) =
β
z-index setting (include
all decimal places). The sum should not be greater than 360 ° ! If it is, then make sure the z-flag
was rotated fully counter-clockwise. If it wasn’t, repeat the procedure from step 15 forward.
22. Using the Step Forward command in the Head Timing tab, increase the angular position by 2 ° in-
crements until the gauge pin clears the dial indicator plunger. After that, support the weight step
upward in 5 ° increments or more; stopping roughly 5 ° -7 ° before reaching the
β
z-index setting
position.
23. At this position, let the weight once again hang freely and use the micro-step command to slowly
increase angular position to exactly
β
z-index setting.
•
Note: It is very important that you don’t overshoot this value. If this happens, rotate back at
least 5 ° before this point and repeat.
Figure 5 - Z-Index LED (Location D50)
24.
Loosen the z-flag and manually rotate it until the z-index LED (located at D50 on the main PCB as
shown in Figure 5 above) changes state. Carefully tighten the flag in place at this transition point
with the LED light off.
•
Note: It is very important that the z-flag is set at a z-shaft angle equal to
β
z-index. The position
may change slightly while the z-flag is tightened. If this happens, simply loosen the flag once
more, and gently rotate the z-shaft at the rear pulley to re-establish the original angular posi-
tion and repeat.
25. The LED must turn off/on at ± 0.2 ° of
β
z-index setting. Use the micro-step command to rotate
the z-shaft down in angular position by at least 2 ° , then forward again and note the angular