Needle Number Measurement
1
.000
2
-.002
3
.000
4
-.00125
5
-.00025
6
-.00025
7
.00025
8
.0005
9
.00075
10
-.005
11
-.00025
12
-.00375
13
-.00325
14
-.00425
15
-.001
16
-.00275
Example of a Completed Worksheet Table
15. The most negative number is your closest needle. If no negative numbers are recorded, then the
needle with value ‘0’ is the closest needle. Using the example above, the closest needle is Needle
14 with a measurement of -.00425.
16. Record this number on masking tape in the chasse, replacing the previous piece of tape with the
closest needle measurements.
17. You need to calculate the total variance to be sure that it is within the total allowed variance
of.006. You do this by adding the most positive number and the most negative number. Using
the example above, you would add -.00425 to +.00075. You get.0035 and this is within the total
allowed variance of.006. If your machine does not fall in this range, you can replace the needle
bar in the closest needle (the most negative needle). If this does not work you need to replace the
needle case assembly.
18. Return the machine to ‘Head Up’ by holding the plunger back and simultaneously pressing the
Adjust and Up keys on your machine keypad.
19.
Remove the Closest Needle fixture.
20. Replace the Bobbin Case.
21. Replace the Needle Plate.