165 of 271
Power Supply Interface Harness Replacement
WARNING!!
This procedure is intended to be performed only by specially trained Melco service
technicians and personnel. Disassembly by untrained individuals will void any warranty protec-
tion and can result in personal injury or damage to the machine.
WARNING!!
Do not attempt to replace or service any component in the rear of the lower bed
without disconnecting the A/C power input cord. Failure to do so will leave the power supply
and power switch energized with dangerous levels of voltage even when turned off and can
result in severe injury from electrical shock.
1. Disconnect the leads from the power supply interface harness from the top wiring block of the
power supply unit.
Figure 1 - Power Supply Interface Connector
2. Use a screwdriver or similar tool and push the retaining clips in and push the white 9-position con-
nector out of the power input assembly plate as shown in Figure 1 above.
3. Push the replacement interface harness connector in place in the same position as shown in Figure
1 above.
Figure 2 - Power Supply Interface Harness Wiring to Power Supply
4. Install the replacement harness to the top wiring block as shown in Figure 1 above. The V- and V+
leads are interchangeable with like labeled V- and V+ leads. Tighten the screws in the wiring block
just enough to hold the wire connectors securely.
Table of Contents
Содержание Bravo