147 of 271
Take Up Lever Replacement
Take up levers require replacement whenever they are damaged in anyway. No fixtures are required to
perform this procedure, but it must be completed by following these instructions explicitly.
Replacement Parts Needed:
• One (1) take up lever assembly (for each take up lever requiring replacement)
Replacement Procedure
1. Remove the needlecase access cover.
2. Remove the needlecase cover.
3. On the left end of the take up lever axis (take up lever shaft), use a black marker and mark on the
axis where the inside edge of the left take up lever mounting block clamps onto the axis.
4. Turn the main power switch ON.
5. Color change to Needle 5.
6. Shut the machine OFF.
7. Remove the two screws mounting the right color change shaft mounting block and loosen the
screw clamping the color change shaft. Remove the mounting block.
Figure 1 - Right Take Up Lever Bar Mounting Block
8. Loosen the top screw in the right take up lever mounting block.
Figure 2 - Right Take Up Lever Bar Mounting Block
9. Loosen the two top screws holding the take up lever bar in the left take up lever mounting block.
Figure 3 - Screws on Take Up Lever bar
Table of Contents
Содержание Bravo