![Melco Bravo Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/melco/bravo/bravo_technical-manual_1767024028.webp)
28 of 271
Hoop Key
The Hoop key is used to move the position of the needle in relation to the hoop.
+
The Hoop Key and the Arrow Up key move the needle position up, towards the top of the
hoop (moves the hoop forward, toward the front of the machine.
+
The Hoop Key and the Arrow Down key move the needle position down, towards the bottom
of the hoop (moves the hoop towards the back of the machine).
+
The Hoop Key and the Arrow Left key moves the needle position to the left (moves the hoop
to the right)
+
The Hoop Key and the Arrow Right key moves the needle position to the right (moves the
hoop to the left)
+
The Hoop Key and the Center key moves the hoop to hoop center position
Step Back Key
The step back key moves the machine backwards on the design (to a lower numbered stitch point).
This allows the operator to restitch a certain portion of a design if needed.
Step Forward Key
The step forward key moves the stitch point in the design forward (to a higher numbered stitch
position).
Laser Key
Press and hold the laser key to turn the laser on. The laser stays on as long as the key is pressed.
+
You can also press and hold the laser key , then press the up arrow to manually feed thread
on the current needle. This function is useful when threading a needle because it can be used to supply
more thread (replacing the need to lift the pinch roller and pull out more thread).
Start Button
Pressing the start button while the machine is not running and is at the start of a design will start the
sewing of the design.
Table of Contents
Содержание Bravo
Страница 1: ...Technical Manual Rev 082115 ...