Revision 1.7.2
Page 3
2.4 Connecting the DSM410
The Maretron DSM410 provides a connection to an NMEA 2000
®
interface through a standard Micro
NMEA 2000
®
connector that can be found on the back of the unit. The NMEA 2000
®
connector is a
five-pin male connector (see Figure 1). You connect the DSM410 to an NMEA 2000
®
network using a
Maretron NMEA 2000
®
cable (or compatible cable) by connecting the female end of the NMEA 2000
®
network cable to the male connector on the DSM410 (note the key on the male connector and
keyway on the female connector). Be sure the cable is connected securely and that the collar on the
cable connector is tightened firmly. Connect the other end of the cable (male) to the NMEA 2000
®
network in the same manner. The DSM410 is designed such that you can plug or unplug it from an
NMEA 2000
®
network while the power to the network is connected or disconnected. Please follow
recommended practices for installing NMEA 2000
®
network products.
Figure 1
– NMEA 2000® Connector Face View
2.4.1 Checking the Connection
Once the NMEA 2000
®
connection to the Maretron DSM410 has been completed, observe the
display to check to see that information is being properly received. One way to verify connectivity is to
enter the device selection menu, which is described in Section 5.2.3.2. Refer to Section 10,
“Troubleshooting”, if no information appears.
Содержание DSM410
Страница 103: ...Revision 1 7 2 Page 87 Figure 75 DSM150 DSM250 DSM410 Remote Device Selection...
Страница 171: ...Revision 1 7 2 Page 155 Figure 159 RAA100 Setting the to Sender Gauge Resistance...
Страница 228: ...DSM410 User s Manual Page 212 Revision 1 7 2 Figure 244 Compass Rose North Up Display...
Страница 248: ...DSM410 User s Manual Page 232 Revision 1 7 2 Figure 274 Favorite Screen Showing Highlighted Switch Breaker...