DSM410
User’s Manual
Page 82
Revision 1.7.2
Figure 66
– DSM150/DSM250/DSM410 Remote Device Selection Screen
The “
NA
” column of the menu displays the node address the device is using.
The “
Manuf
.” column of the menu displays the manufacturer of the device.
The “
Model
” column displays the model number of the device.
The “
SN#
” column displays the serial number of the device, so that any of two or more devices of
the same manufacturer and model number may be distinguished from one another.
The “
Stat
” column indicates whether the device is currently connected to the bus and is
responding to queries (“Online”), or has been disconnected from the bus, has lost power, or for
some other reason is not responding to queries (“Offline”).
The “
Disp
” column indicates whether data from that particular device is accepted for display by
the remote DSM150/DSM250/DSM410
(“On”) or that the remote DSM150/DSM250/DSM410
ignores data transmitted by this device (“Off”). By scrolling to the device and pressing the Enter
key (
), you may then use the Scroll Up (
) and Scroll Down (
) keys to toggle the
“Display” status for this particular device. Once you are satisfied with the state of the “Display”
setting, press the Enter key (
) to accept the setting.
The remote DSM150/DSM250/DSM410 will retain information on devices that have been removed
from the bus or powered down (“Offline”) so that when they are placed back on the bus, they will
assume their prior “Display” setting.
6.9.2 Copy alarms settings from local display
It is possible to copy the alarm settings from a DSM410 unit to a remotely located
DSM150/DSM250/DSM410. This should be done with care because if more than one Alert Source is
monitoring the same parameter, then multiple alerts will be generated when the parameter goes out
of bounds, and each one will need to be independently accepted or cancelled. Any alarms existing on
the remote DSM150/DSM250/DSM410 will be deleted. This command will also copy the SMS (Text)
Phone Book settings. Figure 67 below shows this menu item highlighted.
Содержание DSM410
Страница 103: ...Revision 1 7 2 Page 87 Figure 75 DSM150 DSM250 DSM410 Remote Device Selection...
Страница 171: ...Revision 1 7 2 Page 155 Figure 159 RAA100 Setting the to Sender Gauge Resistance...
Страница 228: ...DSM410 User s Manual Page 212 Revision 1 7 2 Figure 244 Compass Rose North Up Display...
Страница 248: ...DSM410 User s Manual Page 232 Revision 1 7 2 Figure 274 Favorite Screen Showing Highlighted Switch Breaker...