Revision 1.7.2
Page 103
on the fuel flow sensor label. Change this entry
to “Reverse Installation if the direction of the fuel flow
is in the opposite direction as the arrow on the fuel flow sensor label.
6.13.1.3
Channel 1 Installation
Leave this entry at the default value of “Normal Installation” if the flow sensor connected to Channel 1
of the FFM100 is installed such that the direction of the fuel flow is in the same direction as the arrow
on the fuel flow sensor label. Change this entry to “Reverse Installation if the direction of the fuel flow
is in the opposite direction as the arrow on the fuel flow sensor label.
6.13.1.4
Channel 0 Allow negative flow
Leave this entry at the default value
of “Yes” for the FFM100 to output negative fuel flow values if the
direction of fuel flow for the Channel 0 sensor is opposite the direction of the arrow on the fuel flow
sensor label. Set this entry to “No” to output zero for the fuel flow rate if the direction of fuel flow is
opposite the direction of the arrow on the fuel flow sensor label.
6.13.1.5
Channel 1 Allow negative flow
Leave this entry at the default value
of “Yes” for the FFM100 to output negative fuel flow values if the
direction of fuel flow for the Channel 0 sensor is opposite the direction of the arrow on the fuel flow
sensor label. Set this entry to “No” to output zero for the fuel flow rate if the direction of fuel flow is
opposite the direction of the arrow on the fuel flow sensor label.
6.13.1.6
Differential Mode Allow negative flow
Leave this entry at the default value
of “No” for the FFM100 to output zero for the fuel flow rate if the
computed net fuel flow rate is negative.
Set this entry to “Yes” for the FFM100 to output negative
values for the fuel flow rate if the computed net fuel flow rate is negative
6.13.1.7
Installation Description
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter
any information you like here, such as the date the unit was installed, or the location in which it was
installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values
later.
6.13.1.8
NMEA2000 PGN Enable/Disable
The FFM100 Fuel Flow Module transmits a number of the NMEA2000
®
PGNs which can be turned on
or turned off by the DSM410 display. Pressing the
Enter
key with “NMEA2000 PGN
Ena
ble/Disable…” menu item selected causes the DSM410 to display the following screen (Figure
Содержание DSM410
Страница 103: ...Revision 1 7 2 Page 87 Figure 75 DSM150 DSM250 DSM410 Remote Device Selection...
Страница 171: ...Revision 1 7 2 Page 155 Figure 159 RAA100 Setting the to Sender Gauge Resistance...
Страница 228: ...DSM410 User s Manual Page 212 Revision 1 7 2 Figure 244 Compass Rose North Up Display...
Страница 248: ...DSM410 User s Manual Page 232 Revision 1 7 2 Figure 274 Favorite Screen Showing Highlighted Switch Breaker...