DSM410
User’s Manual
Page 68
Revision 1.7.2
6.5.3.3 Instance
From here the instance number used in the message send for this channel may be set.
6.5.3.4 Source
This parameter is present only when the channel has been configured for the function of
Temperature, Pressure, Humidity, or Flow Rate. This parameter selects the type of temperature,
pressure, humidity, or flow rate measurement being performed so that displays can more easily select
the data from the network.
6.5.3.5 Value at 4mA
Program this parameter to match the reading of the current loop transducer when it is sourcing a
current of 4mA. You can determine this value by examining the specification of the transducer being
used.
6.5.3.6 Value at 20mA
Program this parameter to match the reading of the current loop transducer when it is sourcing a
current of 20mA. You can determine this value by examining the specification of the transducer being
used.
6.5.3.7 Data Damping Period
You can configure a damping parameter to smooth the parametric readings or make them more
responsive. The data damping is configurable between 0.1-25.0 seconds. The default data damping
period is 3.0 seconds.
6.6 Maretron DCM100 Configuration
This describes the configuration of the Maretron DCM100 firmware version 1.0.4.
Figure 51
– DCM100 Configuration Screen
Содержание DSM410
Страница 103: ...Revision 1 7 2 Page 87 Figure 75 DSM150 DSM250 DSM410 Remote Device Selection...
Страница 171: ...Revision 1 7 2 Page 155 Figure 159 RAA100 Setting the to Sender Gauge Resistance...
Страница 228: ...DSM410 User s Manual Page 212 Revision 1 7 2 Figure 244 Compass Rose North Up Display...
Страница 248: ...DSM410 User s Manual Page 232 Revision 1 7 2 Figure 274 Favorite Screen Showing Highlighted Switch Breaker...