standard values of resistances for rudder angle senders and for rudders with maximum port and
starboard angles of anything other than 45°.
To perform custom calibration of the rudder angle sender, use the Scroll Up (
) or Scroll Down (
) keys to move the highlighted cursor over the “Custom Calibration…” menu item. Then, press the
Enter key (
) to confirm your selection and begin the calibration process. Figure 151 shows the
DSM410 with the Custom Rudder Calibration menu item highlighted.
Figure 151
– RAA100 Custom Rudder Angle Calibration
The first step in the custom rudder angle sender calibration process is to turn the wheel hard over to
starboard, and to measure the angle or the rudder (angle from center) with a protractor or other
instrument. Use the Increase and Decrease keys until the highlighted rudder angle value is at the
measured value, and then press Enter to accept the value and store it within the RAA100. Figure 152
shows a screenshot of the starboard rudder calibration screen. You may also press the Abort Key (
) to end the calibration process.
Figure 152
– RAA100 Starboard Rudder Angle Calibration
Содержание DSM410
Страница 103: ...Revision 1 7 2 Page 87 Figure 75 DSM150 DSM250 DSM410 Remote Device Selection...
Страница 171: ...Revision 1 7 2 Page 155 Figure 159 RAA100 Setting the to Sender Gauge Resistance...
Страница 228: ...DSM410 User s Manual Page 212 Revision 1 7 2 Figure 244 Compass Rose North Up Display...
Страница 248: ...DSM410 User s Manual Page 232 Revision 1 7 2 Figure 274 Favorite Screen Showing Highlighted Switch Breaker...