Revision 1.7.2
Page 93
6.11.1.2
Instance Temperature
The Data Instance of the Temperature (as sent in PGNs 130310, 130311, and 130312) is set in this
field. Use the
Increase
and
Decrease
buttons to select the correct instance number, and the press
the
Enter
button to store it.
6.11.1.3
Installation Description
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter
any information you like here, such as the date the unit was installed, or the location in which it was
installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values
later. See section 3.3.4 for details on how to enter a textual value.
6.11.1.4
NMEA2000 PGN Enable/Disable
The DST110 transmits several different NMEA2000 PGN
’s which can be turned on or turned off by
the DSM410 display. Pressing the
Enter
key with “NMEA2000 PGN Enable/Disable…” menu item
selected causes the DSM410 to display the following screen.
Figure 83
– DST110 NMEA 2000
®
PGN Enable/Disable Screen
You can enable or disable the transmission of these messages, or set the frequency of transmission
of the message by pressing the Enter key (
) on the message to be configured. Options are:
Off
– The message will not be transmitted
On
– The message will be transmitted at its default NMEA 2000
®
rate.
Select the required option using the
Scroll Up
and
Scroll Down
keys followed by the
Enter
key.
6.11.2
Clear Speed Calibration
The
Clear Speed Calibration
configuration parameter shows you the currently used correction
factor. All measured STW readings are multiplied by this number before being transmitted over the
NMEA 2000
®
network. You can remove the correction factor by pressing the Enter key (
) with the
“Clear Speed Calibration:” menu item selected. And then choose “Clear” using Scroll Up (
) or
Scroll Down (
) keys followed by the Enter key (
). This changes the correction factor back to 1
such that all subsequent measured STW readings are no longer adjusted before begin transmitted
over the NMEA 2000
®
network.
Содержание DSM410
Страница 103: ...Revision 1 7 2 Page 87 Figure 75 DSM150 DSM250 DSM410 Remote Device Selection...
Страница 171: ...Revision 1 7 2 Page 155 Figure 159 RAA100 Setting the to Sender Gauge Resistance...
Страница 228: ...DSM410 User s Manual Page 212 Revision 1 7 2 Figure 244 Compass Rose North Up Display...
Страница 248: ...DSM410 User s Manual Page 232 Revision 1 7 2 Figure 274 Favorite Screen Showing Highlighted Switch Breaker...