Revision 1.7.2
Page 81
6.9 Maretron DSM150/DSM250/DSM410 Configuration
You can use the DSM410 to configure other remotely-located DSM150, DSM250, and DSM410 units
by using the Remote DSM150/DSM250/DSM410 configuration menu as shown in Figure 65 below.
This describes the configuration of the Maretron DSM150/DSM250/DSM410 firmware version 1.7.2.
There are three configurable items for the remote DSM150/DSM250/DSM410
: “Remote Device
Select
ion…”, “Copy device selection from local display”, and “Copy favorite settings from local
display”.
Figure 65
– DSM150/DSM250/DSM410 Remote Configuration Screen
6.9.1 Remote Device Selection
A DSM410 unit can be used to configure a remote DSM150/DSM250/DSM410 to set which NMEA
2000
®
devices are selected for display on the remote DSM150/DSM250/DSM410 unit. In this manner,
multiple devices of the same type may be used on a NMEA 2000
®
network in a fail-safe configuration.
For example, a certain compass unit may be selected from several available compasses for display
on the remote DSM150/DSM250/DSM410. The Remote DSM150/DSM250/DSM410 Device Selection
Menu for an example network configuration can be seen in Figure 66 below.
WARNING
: Do not select multiple devices of the same type for display. This will result in multiple and
possibly conflicting readings.
Содержание DSM410
Страница 103: ...Revision 1 7 2 Page 87 Figure 75 DSM150 DSM250 DSM410 Remote Device Selection...
Страница 171: ...Revision 1 7 2 Page 155 Figure 159 RAA100 Setting the to Sender Gauge Resistance...
Страница 228: ...DSM410 User s Manual Page 212 Revision 1 7 2 Figure 244 Compass Rose North Up Display...
Страница 248: ...DSM410 User s Manual Page 232 Revision 1 7 2 Figure 274 Favorite Screen Showing Highlighted Switch Breaker...