background image

 

DSM410 

User’s Manual  

 

 

Page 62 

 

 

Revision 1.7.2 

6.4 Maretron ALM100 Configuration 

This describes the configuration of the Maretron ALM100 firmware version 1.0.5.  
 

 

Figure 44 

– ALM100 Configuration Screen 

6.4.1 Advanced Configuration 

Advanced Configuration changes some complex parameters within the device, and should only be 
performed by an advanced user. Typically advanced configuration is only done at installation and 
should not need to be done while at sea. 
 

 

Figure 45 

– ALM100 Advanced Configuration Screen 

6.4.1.1  Device Instance 

This entry allows you to program the NMEA 2000 device instance for the unit.  You usually will not 
need to modify the default value of “0” unless you have multiple units on the network. 

6.4.1.2  Installation Description 

This entry allows you to modify the NMEA 2000 installation description text strings.  You can enter 
any information you like here, such as the date the unit was installed, or the location in which it was 

Содержание DSM410

Страница 1: ...NMEA 2000 Multi function Color Graphic Display User s Manual Revision 1 7 2 Copyright 2017 Maretron LLP All Rights Reserved Maretron LLP 9014 N 23rd Ave 10 Phoenix AZ 85021 7850 http www maretron com...

Страница 2: ...DSM410 User s Manual Page ii Revision 1 7 2 Revision History Revision Description 1 7 2 Original document...

Страница 3: ...3 3 2 Choosing a Value from a List 6 3 3 3 Entering a Numeric Value 6 3 3 4 Entering a Textual Value 6 3 4 Settings Lock Mode 8 4 Important Concepts 9 4 1 Favorite Screens 9 4 2 Categories and Data T...

Страница 4: ...2 6 Favorite Screens Setup Menu 36 5 2 7 Units Menu 41 5 3 Control Mode 45 6 Device Configuration 47 6 1 Airmar Depth Speed Temperature Transducers 50 6 1 1 Advanced Configuration 50 6 1 2 Device Ins...

Страница 5: ...lection 81 6 9 2 Copy alarms settings from local display 82 6 9 3 Copy device selection from local display 83 6 9 4 Copy display settings from local display 84 6 9 5 Copy favorite settings from local...

Страница 6: ...Maretron FPM100 Configuration 113 6 14 1 Advanced Configuration 113 6 14 2 Channel 0 5 115 6 15 Maretron GPS100 Configuration 122 6 15 1 Advanced Configuration 123 6 15 2 Cold Start GPS 127 6 15 3 GP...

Страница 7: ...stance 161 6 22 4 Channel Configuration 161 6 23 Maretron SMS100 Configuration 162 6 23 1 Advanced Configuration 162 6 23 2 Label 163 6 23 3 Test 164 6 24 Maretron SSC200 SSC300 Configuration 165 6 24...

Страница 8: ...Password 201 6 31 4 DHCP 201 6 31 5 IP Address 201 6 31 6 Subnet Mask 201 6 31 7 Default Gateway 202 6 31 8 Default DNS 202 6 32 Maretron WSO100 Configuration 202 6 32 1 Advanced Configuration 202 6...

Страница 9: ...rt Type 236 8 3 3 Priority 236 8 3 4 Trigger Source 237 8 3 5 Description 237 8 3 6 Location 237 8 3 7 Trigger Configuration 237 8 3 8 Local Audible 251 8 3 9 Tone 252 8 3 10 Remote Annunciators 252 8...

Страница 10: ...een Format 38 Figure 25 Setting the Auto Change Interval 38 Figure 26 Selecting the Data Category 39 Figure 27 Selecting the Data to be displayed 39 Figure 28 DSM410 Units Menu 41 Figure 29 Device Con...

Страница 11: ...re 69 DSM150 DSM250 DSM410 Copy display settings from local display 84 Figure 70 DSM150 DSM250 DSM410 Copy favorite settings from local display 84 Figure 71 Favorite Settings Transfer Completion Scree...

Страница 12: ...ing Antenna Altitude on a GPS100 123 Figure 116 Configuring Satellite Elevation Mask on a GPS100 124 Figure 117 Configuring PDOP Mask on a GPS100 125 Figure 118 Configuring SNR Mask on a GPS100 125 Fi...

Страница 13: ...EA 2000 PGN Enable Disable Screen 160 Figure 167 SIM100 Channel Configuration Screen 161 Figure 168 SMS100 Configuration Screen 162 Figure 169 SMS100 Advanced Configuration Menu 162 Figure 170 SMS100...

Страница 14: ...stom Calibration of the Tank Level Monitor 190 Figure 213 Tank Levels Calibration Capacity Estimation 191 Figure 214 Empty Level Calibration 191 Figure 215 Intermediate Level Calibration 192 Figure 21...

Страница 15: ...lay 223 Figure 260 Time hh mm Display 223 Figure 261 Time hh mm ss Display 224 Figure 262 VDR Status Display 224 Figure 263 Weather Display 225 Figure 264 Wind Rose Display 226 Figure 265 Moon Phase D...

Страница 16: ...Annunciator Enable Disable 252 Figure 297 SMS Text Settings Screen 253 Figure 298 SMS Text Phone Number x Screen 253 Figure 299 Deleting an Alert 255 Figure 300 Deleting Alert List 255 Figure 301 Dele...

Страница 17: ...ctions for installation configuration and usage of the Maretron DSM410 in order to ensure optimal performance 1 2 Firmware Revision This manual corresponds to DSM410 firmware revision 1 7 2 1 3 DSM410...

Страница 18: ...easy access to the rear side of the mounting surface The steps for this type of mounting are as follows 1 Attach the Mounting Template see Section 13 to the surface where the DSM410 is to be located...

Страница 19: ...ecurely and that the collar on the cable connector is tightened firmly Connect the other end of the cable male to the NMEA 2000 network in the same manner The DSM410 is designed such that you can plug...

Страница 20: ...elow Figure 2 DSM410 Power Up Screen Alternatively you may power down the DSM410 by pressing and holding the power key see Section 3 2 below for details 3 2 Turning the DSM410 Off To turn the DSM410 o...

Страница 21: ...ht brightness between three programmed brightness levels see Section 5 2 4 3 on page 32 for details while a long press cycles the DSM250 through 8 programmable color palettes see Section 5 2 4 4 on Pa...

Страница 22: ...Choosing a Value from a List When editing a value chosen from a list the keys on the DSM410 keypad have the following functions Power Key turns the DSM410 off see Section 3 1 on page 4 for details Bac...

Страница 23: ...ton top return to the choices on the left To append a numeral use the Scroll Up and Scroll Down buttons to select Numeric and then press Enter to go across to the numbers Now use the Scroll Up and Scr...

Страница 24: ...The DSM410 has a settings lock mode in which the settings of the DSM410 cannot be changed To enter the lock mode do the following steps 1 Begin with the DSM410 powered off 2 Press and hold the Up and...

Страница 25: ...settings data to display and formats in which to display the data The DSM410 supports up to 16 different favorite screens 4 2 Categories and Data Types The DSM410 is capable of displaying many types...

Страница 26: ...L N Voltage displays average line to neutral RMS voltage of the AC power on the generator Average L L Voltage displays average line to line RMS voltage of the AC power on the generator Total Real Powe...

Страница 27: ...utility Total Apparent Power displays apparent power output by the utility Total Power Factor displays power factor of the utility Total kWH Export displays total energy produced by the utility for th...

Страница 28: ...e DSM410 supports the display of information for up to 64 DC sources including alternators batteries solar cells wind generators etc with special parameters for batteries i e State of Charge Time Rema...

Страница 29: ...14 for details Hardware ON Timer displays the value of a hardware timer in Maretron s DCR100 SIM100 and RIM100 that accumulates the elapsed time that the indicator has spent in the ON state This time...

Страница 30: ...nt dew point based on air temperature and humidity Temp Engine Room displays the air temperature from a sensor mounted in an engine room Temp Inside displays the air temperature from a sensor mounted...

Страница 31: ...displays total fuel remaining in all fuel tanks specified within the favorite screen setup see Section 5 2 6 4 2 In order for the DSM410 to properly calculate total fuel remaining tank monitors connec...

Страница 32: ...to true or magnetic north depending on the unit setting of the heading parameter see Section 5 2 7 1 Rate of Turn displays the angular rate of rotation of the vessel about the vertical axis Variation...

Страница 33: ...otational Rate displays rotational rate e g shaft speed Velocity displays linear velocity 4 2 19 Navigation The DSM410 is not a primary navigation device that is it does not provide means for entering...

Страница 34: ...of the vessel s rudder as indicated by the rudder sensor as well as the angle to which the rudder has been commanded by an autopilot or steering device 4 2 22 SMS Text Status Status displays the stat...

Страница 35: ...al time offset see Section 5 2 7 12 on page 43 for details on how to set the local time offset UTC Date displays the current date referenced to Universal Time Coordinated Moon Phase displays the phase...

Страница 36: ...rotation about the horizontal axis parallel to the ship s keel Trim Tabs displays the position of the vessel s trim tabs Trim Tab Port displays the position of the port trim tab Trim Tab Starboard di...

Страница 37: ...Revision 1 7 2 Page 21 SOG depending on the unit setting of the Wind True Vessel Ref Parameter see Section 5 2 7 6...

Страница 38: ...ctive and always appear above the warnings on the Alert Status Screen Warning A warning is a type of alert announcing a condition requiring non immediate attention for precautionary reasons Warnings a...

Страница 39: ...and is still present and the operator has not accepted the alert An active alert is indicated by a flashing indicator on the Alert Status Screen and by a flashing colored box at the top right of the D...

Страница 40: ...e time specified in the Set Delay field Course Alert The alert will become active if the monitored course differs from the Reference Direction by more than the Offset COG Set Point for longer than the...

Страница 41: ...ay can show any displayable data in any display type supported by that data In favorite screens mode the DSM410 can operate in one of two ways Manual mode a particular favorite screen remains on the d...

Страница 42: ...lowing structure Alert Setup 5 2 1 Add New Alert 8 2 Delete Alert 8 4 Edit Alert 8 5 Operating Mode 8 6 SMS Text Phone Book 0 Advanced Configuration 8 8 Restore Factory Defaults 8 9 Alert Status 5 2 2...

Страница 43: ...be received The available options within the Configuration screen are shown in Figure 8 Figure 8 Configuration Screen 5 2 3 1 Device Configuration The ability to calibrate and configure other devices...

Страница 44: ...es Online or has been disconnected from the bus has lost power or for some other reason is not responding to queries Offline The Display column indicates whether data from that particular device is ac...

Страница 45: ...lly advanced configuration is only done at installation and should not need to be done while at sea Figure 11 DSM410 Advanced Configuration 5 2 4 1 1 Installation Description This entry allows you to...

Страница 46: ...re 12 DSM410 Primary Device Selection 5 2 4 1 3 Refresh Network Information The Device Configuration 5 2 3 1 and Device Selection 5 2 3 2 menus display a list of devices that have been detected on the...

Страница 47: ...nected network given in bits per second bps Voltage the network voltage as measured by the DSM410 in Volts Traffic the percent usage of the total available bandwidth measured by the DSM410 Receive Rat...

Страница 48: ...Low Medium and High brightness levels The value that appears next to the appropriate setting is measured in percent of full brightness The Backlight menu can be seen in Figure 15 below Figure 15 Back...

Страница 49: ...ghts key when the DSM410 is operating in favorite screens mode Change the Color Set back to On to enable this color palette Notice that Color Set 1 has a white background 100 Red 100 Green and 100 Blu...

Страница 50: ...enter the demo mode while programming this option for Off Normal Use Mode will cause the DSM410 to return to using data from the NMEA 2000 bus In order to be able to demonstrate all of the DSM410 s ca...

Страница 51: ...nguages is planned for future firmware releases To change the currently used language use the Scroll Up or Scroll Down keys to move the highlight to the Language menu item and then press the Enter key...

Страница 52: ...s in which the DSM410 will display the next higher or lower numbered favorite screen respectively that is enabled for Manual mode Figure 21 Setting the Favorite Screens Mode 5 2 6 Favorite Screens Set...

Страница 53: ...will be displayed taking up the entire screen 2 3 Top 1 3 Bottom two parameters will be displayed the first occupying the top 2 3 of the screen and the second occupying the bottom 1 3 of the screen 1...

Страница 54: ...creen Four Quarters four parameters will be displayed the first occupying the upper left hand corner of the screen the second occupying the upper right hand corner of the screen the third occupying th...

Страница 55: ...pt this category at which time the highlight will move to the data type field where you can display the particular data type from the selected category to be displayed as shown in Figure 27 Figure 27...

Страница 56: ...Section 7 25 on page 229 5 2 6 4 2 Instance Instance is used to specify which product on the network will be used as the source of the displayed information For example there may be two GPS s on the n...

Страница 57: ...earing information is displayed in true or magnetic measurements True heading can only be displayed if a variation is available on the NMEA 2000 bus If the DSM410 is not showing heading or COG i e no...

Страница 58: ...ted information Units that may be selected are the following Knots Miles Hour Km Hour Beaufort Meters second 5 2 7 6 Wind True Vessel Ref This menu items allows you to select whether the true wind dir...

Страница 59: ...information Units that may be selected are the following Liters Imperial Gallons UK Gallons Gallons US Gallons 5 2 7 11 Time Format This menu item allows you to select whether measurements indicating...

Страница 60: ...the display of resistance Units that may be selected include the following Ohms Kilohms 5 2 7 17 Motion Distance This menu item allows you to select the units to be used for the display of distance U...

Страница 61: ...of angular acceleration Units that may be selected include the following Degrees Second2 Degrees Minute2 Radians Second2 5 3 Control Mode Control mode may be entered from the favorite screens mode of...

Страница 62: ...these steps to reset the appropriate display 1 Press the Enter key for approximately one second This will place the display into Control mode and one of the controllable items on the screen will be hi...

Страница 63: ...etron Depth Speed Temp Transducer DST110 reset trip log set depth offset speed calibration and temperature offset Maretron Engine Monitoring System EMS100 set the gauge types for boost pressure drive...

Страница 64: ...able disable individual NMEA 2000 PGN transmissions Maretron Tank Level Adapter TLA100 set tank type and tank number set operating mode set tank capacity and calibrate for irregular shaped tanks Maret...

Страница 65: ...ays the manufacturer of the device The Model column displays the model number of the device The SN column displays the serial number of the device so that any of two or more devices of the same manufa...

Страница 66: ...tion functions are supported not all functions apply to every model of transducer Reset trip log Set depth Offset Perform Speed Calibration Program Temperature Offset Figure 30 Airmar Depth Speed Temp...

Страница 67: ...isable menu item selected causes the DSM410 to display the NMEA2000 PGN Enable Disable screen You can enable or disable the transmission of these messages or set the frequency of transmission of the m...

Страница 68: ...and calm winds Finally use the Increase and Decrease keys to adjust the display value until it matches the known speed of the boat Press the Accept key to accept the value when you are satisfied If y...

Страница 69: ...ance from the waterline to the depth of the depth transducer The DSM410 will then add the measured depth of the water as seen by the depth transducer to the programmed offset value to produce the tota...

Страница 70: ...program multiple displays each with the corresponding offset information as the information is stored at a single place at the source 6 1 10 Trip Log The DSM410 is capable of clearing the trip log co...

Страница 71: ...ngle entry Trim Tabs Calibration Figure 36 EP 30 Trim Tabs Configuration Screen 6 2 1 Trim Tabs Calibration The Bennett EP 30 NMEA1 trim tabs calibration opening screen is shown in Figure 37 below The...

Страница 72: ...ping in order for the calibration process to succeed Figure 38 EP 30 Intermediate Calibration Screen After you have lowered both trim tabs to their full down position and a few seconds have elapsed th...

Страница 73: ...be performed by an advanced user Typically advanced configuration is only done at installation and should not need to be done while at sea Figure 41 ACM100 Advanced Configuration Screen 6 3 1 1 Curren...

Страница 74: ...ormal Install to Inverse Install to correct for this Valid options are Inverse Install Normal Install Use the Scroll Up and Scroll Down buttons to select the correct option and then press Enter to sav...

Страница 75: ...it to a value in the range of 0 2 seconds to 10 seconds Use the Increase and Decrease buttons to select the correct option and then press Enter to save the value 6 3 1 9 Installation Description This...

Страница 76: ...3 Phase Y Phase A B C use this value when power is connected via the three hot wires 120 out of phase with each other and single neutral wire from a three phase Y connected circuit 6 3 3 AC Device Typ...

Страница 77: ...ced by a Generator or a Utility Pressing the Enter key while this item is highlighted will start the process to reset this value to zero The following confirmation screen is displayed Figure 43 Reset...

Страница 78: ...figuration is only done at installation and should not need to be done while at sea Figure 45 ALM100 Advanced Configuration Screen 6 4 1 1 Device Instance This entry allows you to program the NMEA 200...

Страница 79: ...ssing the Enter key on the message to be configured Options are Disable The Annunciator message will not be transmitted Default The Annunciator message will be transmitted at its default NMEA2000 rate...

Страница 80: ...User s Manual Page 64 Revision 1 7 2 6 4 4 Test Annunciator The Annunciator may be tested by scrolling the cursor to highlight this entry and then pressing the Enter button The ALM100 will emit a sing...

Страница 81: ...is only done at installation and should not need to be done while at sea Figure 48 CLM100 Advanced Configuration Screen 6 5 1 1 Device Instance This entry allows you to program the NMEA 2000 device i...

Страница 82: ...the frequency of transmission of the message by pressing the Enter key on the message to be configured Options are Disable The message will not be transmitted Default The message will be transmitted a...

Страница 83: ...y different types This field allows you to select the type of parameter that is being monitored by this channel You may select from the following parameter types please refer to the CLM100 User s Manu...

Страница 84: ...transducer when it is sourcing a current of 4mA You can determine this value by examining the specification of the transducer being used 6 5 3 6 Value at 20mA Program this parameter to match the read...

Страница 85: ...600 S Select the required transducer using the Scroll Up and Scroll Down keys followed by the Enter key 6 6 1 2 Device Instance This entry allows you to program the NMEA 2000 device instance for the u...

Страница 86: ...e message will be transmitted at the period specified Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key 6 6 1 5 Restore Factory Defaults This option restore...

Страница 87: ...d Figure 55 Current Sensor Zero Offset Calibration Complete Screen Press the Back button to return to the previous menu 6 6 3 DC Type You can configure the DCM100 as to what type of DC power source it...

Страница 88: ...ttery generally increases with increasing temperature So that the DCM100 can properly calculate the battery s state of charge program this parameter with the increase in battery capacity in percent pe...

Страница 89: ...rged from the battery before the battery becomes discharged By default the DCM100 considers a battery to be discharged when its state of charge reaches the Time Remaining Floor value which is by defau...

Страница 90: ...ters within the device and should only be performed by an advanced user Typically advanced configuration is only done at installation and should not need to be done while at sea Figure 57 DCR100 Advan...

Страница 91: ...e 59 DCR100 Current Sensor Zero Offset Calibration Completion Screen Press the Back button to return to the previous menu 6 7 1 2 Device Instance This entry allows you to program the NMEA 2000 device...

Страница 92: ...le Disable Screen 6 7 1 5 Restore Factory Defaults This option restores all settings on the device to their factory default state 6 7 2 Device Label This entry allows you to assign a text label to the...

Страница 93: ...ode is Unlocked In the Unlocked mode the channel may be turned on and off from network display devices By setting the Switch Lock mode of the channel to Lock then channel will not change state until t...

Страница 94: ...g Mode The operating mode of each channel may be set to either DCR DC Relay in which case the state of the channel is controlled by Circuit Breaker Switch controls in N2KView or Switch Breaker favorit...

Страница 95: ...ice Selection A DSM410 unit can be used to configure a remote DSM200 to set which NMEA 2000 devices are selected for display on the remote DSM200 unit In this manner multiple devices of the same type...

Страница 96: ...cted from the bus has lost power or for some other reason is not responding to queries Offline The Disp column indicates whether data from that particular device is accepted for display by the remote...

Страница 97: ...150 DSM250 DSM410 Remote Configuration Screen 6 9 1 Remote Device Selection A DSM410 unit can be used to configure a remote DSM150 DSM250 DSM410 to set which NMEA 2000 devices are selected for display...

Страница 98: ...transmitted by this device Off By scrolling to the device and pressing the Enter key you may then use the Scroll Up and Scroll Down keys to toggle the Display status for this particular device Once yo...

Страница 99: ...py the device selection settings from a DSM410 unit to a remotely located DSM150 DSM250 DSM410 In this way it is possible to make all device selection changes on a single DSM150 DSM250 DSM410 unit and...

Страница 100: ...lecting this menu item and pressing Enter all the favorite screen settings will be copied from the local DSM150 DSM250 DSM410 to the selected remote DSM150 DSM250 DSM410 unit After copying favorite sc...

Страница 101: ...rations from local display 6 9 7 Copy all settings from local display This is the single operation that makes it easy to have multiple DSM150 DSM250 DSM410 displays on a boat Set one DSM150 DSM250 DSM...

Страница 102: ...from local display 6 9 8 Label The Label of the DSM150 DSM250 DSM410 is used by the Alert System to identify the source of an alert Here the label can be changed using the method described in section...

Страница 103: ...Revision 1 7 2 Page 87 Figure 75 DSM150 DSM250 DSM410 Remote Device Selection...

Страница 104: ...00 Configuration Screen 6 10 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced confi...

Страница 105: ...ough water STW initial accuracy is significantly affected by the location or placement of the DST100 within the hull The DSM410 can correct for these inaccuracies using the speed calibration procedure...

Страница 106: ...gative value equal to the distance between the DST100 and the bottom of the keel The display will then subtract the programmed offset from the measured depth of the water as seen by the DST100 showing...

Страница 107: ...d will complete the operation Resetting the trip log zeroes the DST100 s trip log such that all displays receive a zeroed value i e you don t have to perform the operation from other display locations...

Страница 108: ...1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced configuration is only done at ins...

Страница 109: ...ed causes the DSM410 to display the following screen Figure 83 DST110 NMEA 2000 PGN Enable Disable Screen You can enable or disable the transmission of these messages or set the frequency of transmiss...

Страница 110: ...e until it matches the known speed of the boat Press the Accept key to accept the value when you are satisfied If you do not wish to perform speed calibration at this time press the Abort key and the...

Страница 111: ...depth of the DST110 The DSM410 will then add the measured depth of the water as seen by the DST110 to the programmed offset value to produce the total water depth If you are interested in the depth of...

Страница 112: ...e corresponding offset information as the information is stored at a single place at the source 6 11 7 Trip Log The DSM410 is capable of clearing the trip log counter within a DST110 depth speed tempe...

Страница 113: ...st Screen Figure 89 EMS100 Configuration Screen Second Screen 6 12 1 Engine Instance This entry allows you to program the NMEA 2000 device instance for the unit You usually will not need to modify the...

Страница 114: ...enders vary from their specified values This setting allows you to apply an offset to the resistance value of the boost pressure sender in order to allow you to bring the digital value reported by the...

Страница 115: ...option if there is no oil pressure gauge present YANMAR YANMAR W THRESHOLD YANMAR VDO YANMAR VDO W THRESHOLD Select the required option using the Scroll Up and Scroll Down keys followed by the Enter k...

Страница 116: ...ons are Disabled select this option if there is no water temperature sender present YANMAR YANMAR VDO Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key 6 12...

Страница 117: ...lses per revolution in order to correctly calculate engine RPM Use this setting to program the EMS100 with the number of flywheel teeth or alternator pulses per revolution for the engine to which the...

Страница 118: ...n advanced user Typically advanced configuration is only done at installation and should not need to be done while at sea Figure 91 FFM100 Advanced Configuration 6 13 1 1 Device Instance This entry al...

Страница 119: ...t value of Yes for the FFM100 to output negative fuel flow values if the direction of fuel flow for the Channel 0 sensor is opposite the direction of the arrow on the fuel flow sensor label Set this e...

Страница 120: ...ault state 6 13 2 Device Label A label may be assigned to the FFM100 as an aid to identifying the device over the network Typically this label will describe the location of the FFM100 6 13 3 Operating...

Страница 121: ...low Figure 93 FFM100 Channel 0 First Configuration Screen Differential Mode Figure 94 FFM100 Channel 0 Second Configuration Screen Differential Mode 6 13 4 1 1 Channel Supply Return You may select whe...

Страница 122: ...tance Program this parameter to match the desired instance number of the temperature reading for this channel You can program this parameter to any value between 0 and 252 The default value for this p...

Страница 123: ...l Maretron display products will display this label text when you are selecting data to display 6 13 4 2 Channel 0 Configuration Menu Two Independent Sensors Mode This section describes the Channel 0...

Страница 124: ...the flow sensor connected to this channel 6 13 4 2 5 Data Damping Period You can configure a damping parameter to smooth the flow rate readings or make them more responsive The data damping is configu...

Страница 125: ...Instance Program this parameter to match the desired instance number of the volume reading for this channel You can program this parameter to any value between 0 and 252 The default value for this par...

Страница 126: ...efault value for this parameter is 0 033 C which corresponds to Diesel fuel This parameter is not available when the Operating Mode is set to Two Individual Flow Sensors 6 13 5 1 4 Temperature Instanc...

Страница 127: ...nnel 1 First Configuration Screen Two Independent Sensors Mode Figure 99 FFM100 Channel 1 Second Configuration Screen Two Independent Sensors Mode 6 13 5 2 1 Sensor You may select whether this channel...

Страница 128: ...y to reset the total volume recorded to zero 6 13 5 2 7 Temperature Instance Program this parameter to match the desired instance number of the temperature reading for this channel You can program thi...

Страница 129: ...me Label Program this parameter with a text string which identifies the particular volume parameter being monitored by this channel Maretron display products will display this label text when you are...

Страница 130: ...iption text strings You can enter any information you like here such as the date the unit was installed or the location in which it was installed for later reference Tools such as Maretron N2KAnalyzer...

Страница 131: ...Enter key 6 14 1 4 Restore Factory Defaults This option restores all settings on the device to their factory default state 6 14 2 Channel 0 5 This submenu contains configuration parameters for each o...

Страница 132: ...y examining the specification of the pressure transducer being used 6 14 2 1 4 Pressure at 20mA Program this parameter to match the pressure reading of the pressure transducer when it is sourcing a cu...

Страница 133: ...nce of the sender with the fluid levels Custom calibration is necessary for non rectangular tanks and for non standard values of resistances for tank level senders To perform custom calibration of the...

Страница 134: ...first calibration step Enter the first calibration point with an empty tank 0 0 Gallons liters by pressing the Accept key The Current Point highlight will advance to the next point Figure 107 Empty L...

Страница 135: ...will also adjust the tank capacity to the currently indicated level Figure 109 below shows the calibration screen at the last point with the full tank level and thus the tank capacity set to 101 gall...

Страница 136: ...Depth enter the depth of the fluid when the tank is full this is the distance from the surface of the fluid to the bottom of the tank Fluid Density enter the density of the fluid whose depth is being...

Страница 137: ...channel s Function has been set to Pressure Vacuum mode The Channel 0 5 Pressure Vacuum Mode menu is shown below Figure 112 FPM100 Channel Pressure Vacuum Mode Configuration 6 14 2 2 1 Function You c...

Страница 138: ...data damping period is 16 0 seconds If the channel s Function is set to Pressure Vacuum the default data damping period is 3 0 seconds 6 15Maretron GPS100 Configuration This describes the configurati...

Страница 139: ...e 114 GPS100 Advanced Configuration Screen 6 15 1 1 Device Instance The Device Instance will be used to identify the GPS100 device on the network Unless there are multiple GPSs on the network this sho...

Страница 140: ...m selected which causes the screen shown in Figure 116 to be displayed Figure 116 Configuring Satellite Elevation Mask on a GPS100 The allowable values for Elevation Mask are between 90 and 90 This nu...

Страница 141: ...ained Disabling the PDOP Mask by setting the value to will cause the GPS100 to report any position fixes obtained regardless of the accuracy of the fix 6 15 1 5 SNR Mask The DSM410 is capable of setti...

Страница 142: ...DSM410 display Pressing the Enter key with NMEA2000 PGN Enable Disable menu item selected causes the DSM410 to display the screen shown in Figure 119 Figure 119 GPS100 NMEA 2000 PGN Enable Disable Sc...

Страница 143: ...elected which causes the screen shown in Figure 121 to be displayed This will cause the GPS100 to discard all position and satellite data and compute a position fix Figure 121 Performing a Cold Start...

Страница 144: ...ault which allows the GPS to report any available data regardless of the quality of the fix 6 15 4 Device Label A label may be assigned to the GPS100 as an aid to identifying the device over the netwo...

Страница 145: ...23 Configuring SBAS on a GPS100 The allowable option for SBAS configuration are either Disable which causes the GPS100 not to use SBAS satellites or Enable which causes the GPS100 to use SBAS satellit...

Страница 146: ...tore Factory Defaults configuration which allows you to return the GPS200 to the factory settings Figure 124 GPS200 Configuration Screen 6 16 1 Advanced Configuration Advanced Configuration changes so...

Страница 147: ...lected causes the DSM410 to display the screen shown in Figure 119 Figure 126 GPS200 NMEA 2000 PGN Enable Disable Screen You can enable or disable specific transmissions by scrolling or through the di...

Страница 148: ...compute a position fix Figure 128 Performing a Cold Start of the GPS200 6 16 3 Device Label A label may be assigned to the GPS200 as an aid to identifying the device over the network Typically this w...

Страница 149: ...29 Configuring SBAS on a GPS200 The allowable option for SBAS configuration are either Disable which causes the GPS200 not to use SBAS satellites or Enable which causes the GPS200 to use SBAS satellit...

Страница 150: ...130 IPG100 Configuration Screen 1 1 2 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanc...

Страница 151: ...2KServer running on the IPG100 The following sections describe the entries in this menu Figure 132 IPG100 N2KServer Information Screen 6 17 1 3 1 Client List For each N2KView client connected to the I...

Страница 152: ...nses This entry shows the number of platinum licenses in use followed by a slash followed by the total number of platinum licenses 6 17 1 3 5 Basic Licenses This entry shows the number of basic licens...

Страница 153: ...KView client whether it is a Windows PC or an iOS or Android smartphone or tablet If you have an active Maretron Cloud Services account you must change this setting to Enable so that the IPG100 will c...

Страница 154: ...s in the subnet mask the values define the network and must be the same The most common value is 255 255 255 0 If the DHCP parameter is set to Yes you do not need to configure this parameter If the DH...

Страница 155: ...1 1 Data Damping In order to smooth the results viewed on a display you may individually change the data damping period that the J2K100 uses when sending fuel rate and tachometer engine RPM informati...

Страница 156: ...tic messages use the Scroll Up or Scroll Down keys to move the highlighted cursor to the J1939 Diagnostic Messages menu item Then press the Enter key to move the highlight to the value field which dis...

Страница 157: ...he DSM410 to display the following screen Figure 139 J2K100 NMEA 2000 PGN Enable Disable Screen You can enable or disable specific transmissions by scrolling or through the different transmitted messa...

Страница 158: ...Address see section 6 18 4 identifies the engine on the J1939 network the Engine Instance identifies the engine to the NMEA2000 network Figure 140 J2K100 Engine Instance Configuration Use the Scroll...

Страница 159: ...nce identifier to allow display devices to distinguish it from other air conditioners or icemakers on the network The AC Icemaker menu item allows you to configure the air conditioner or instance iden...

Страница 160: ...a single J1939 engine genset or a single transmission and the NMEA 2000 network This setting identifies the J1939 source address of the engine genset and a transmission for which the J2K100 will serve...

Страница 161: ...een To update the list after adding a device highlight this entry and press the Enter button 6 19Maretron NBE100 Configuration The DSM410 is capable of configuring the Maretron NBE100 Network Bus Exte...

Страница 162: ...text strings You can enter any information you like here such as the date the unit was installed or the location in which it was installed for later reference Tools such as Maretron N2KAnalyzer allow...

Страница 163: ...stance This entry allows you to program the NMEA 2000 device instance for the unit You usually will not need to modify the default value of 0 unless you have multiple units on the network 6 20 1 2 Ins...

Страница 164: ...mission of the Rudder message by pressing the Enter key on the message to be configured Options are Disable The status message will not be transmitted Default The status message will be transmitted at...

Страница 165: ...tion Options There are three methods of calibrating the rudder angle sender 6 20 3 1 Custom Calibration The Custom Calibration setting will provide the most accurate rudder angle readings under any ci...

Страница 166: ...Custom Rudder Calibration menu item highlighted Figure 151 RAA100 Custom Rudder Angle Calibration The first step in the custom rudder angle sender calibration process is to turn the wheel hard over to...

Страница 167: ...e wheel hard over to port and to measure the angle or the rudder angle from center with a protractor or other instrument Use the Increase and Decrease keys until the highlighted rudder angle value is...

Страница 168: ...udder number must be configured For a vessel with a single rudder the number should be set to 0 For a vessel with two rudders the port rudder should be set to 0 and the starboard rudder should be set...

Страница 169: ...formed correctly in order for the RAA100 to produce correct angle measurements A screenshot showing configuration of the operating mode appears in Figure 157 below To configure the operating mode use...

Страница 170: ...d finally press the Enter key to confirm your selection and store the value within the RAA100 Figure 158 RAA100 Setting the to Sender Gauge Resistance 6 20 7 Gauge Resistance to Sender If the desired...

Страница 171: ...Revision 1 7 2 Page 155 Figure 159 RAA100 Setting the to Sender Gauge Resistance...

Страница 172: ...igure 160 RIM100 Configuration Screen 6 21 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically...

Страница 173: ...able Disable Screen You can enable or disable the transmission of the Binary Switch Status message or set the frequency of transmission of the message by pressing the Enter key on the message to be co...

Страница 174: ...alid Modes are Disable the channel is not being used Enable the channel is being used Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key 6 21 4 2 Label A lab...

Страница 175: ...SIM100 Configuration Screen 6 22 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced...

Страница 176: ...2000 PGN Enable Disable Screen You can enable or disable the transmission of the Binary Switch Status message or set the frequency of transmission of the message by pressing the Enter key on the mess...

Страница 177: ...ault condition See the manual for details Valid Modes are Disable the channel is not being used End Of Line Resistor an open circuit is a fault condition No End Of Line Resistor an open circuit is not...

Страница 178: ...e displayed Figure 168 SMS100 Configuration Screen 6 23 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced us...

Страница 179: ...gure 170 SMS100 NMEA 2000 PGN Enable Disable Screen You can enable or disable the transmission of the various messages or set the frequency of transmission of the messages by pressing the Enter key on...

Страница 180: ...ength is shown on a scale of one to five bars Bit Error Rate This entry shows the bit error rate of the cellular network connection This figure may be requested by Maretron technical support personnel...

Страница 181: ...gure 172 below Figure 172 SSC200 SSC300 Configuration Screen 6 24 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an a...

Страница 182: ...0 baud This value may be changed by selecting the Baud Rate option in the menu and pressing Enter The use the Scroll Up and Scroll Down buttons to select the desired baud rate and press Enter to save...

Страница 183: ...nd variation The SSC200 SSC300 always has magnetic heading available when variation is not available timeout or invalid the variation field is set to N A The default value of 5 0 seconds should be ade...

Страница 184: ...isabled Off using the Scroll Up or Scroll Down keys followed by the Enter key 6 24 1 5 Restore Factory Defaults This option restores all settings on the device to their factory default state 6 24 2 In...

Страница 185: ...ly the SSC200 SSC300 is mounted so that the label on the compass is facing up and the NMEA 2000 and NMEA 0183 connectors are facing towards the bow of the vessel A recent version of SSC200 SSC300 firm...

Страница 186: ...180 SSC200 SSC300 Magnetic Deviation Calibration Start Screen Once you have begun the turn press Begin to start the calibration procedure If you do not wish to perform magnetic deviation calibration a...

Страница 187: ...en will appear indicating this and you should repeat the calibration procedure 6 24 6 Magnetic Deviation Status Pressing the Enter key with the Magnetic Variation Status menu item selected causes the...

Страница 188: ...by pressing the Enter key with the Rate of Turn Zero Offset Calibration menu item selected which causes the DSM410 to display the screen shown in Figure 184 The Rate of Turn Offset Calibration should...

Страница 189: ...183 or NMEA 2000 factory default You should need to alter this setting only if There are variation sources available on both the NMEA 2000 and NMEA 0183 interfaces or There is no magnetic variation so...

Страница 190: ...n Source menu item selected This highlights the next field where you select Manual Entry by scrolling or through the options until you reach Manual Entry Pressing the Enter key with the Manual Entry m...

Страница 191: ...e only in magnetic heading format WARNING Magnetic variation changes as your location on the earth changes therefore magnetic variation should be adjusted with changes in position Neither the DSM410 n...

Страница 192: ...guration Screen 6 25 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced configuration...

Страница 193: ...n Figure 191 Figure 191 TLA100 NMEA 2000 PGN Enable Disable Screen You can enable or disable the transmission of the Fluid Level message or set the frequency of transmission of the message by pressing...

Страница 194: ...city After you have pressed the Enter key a confirmation screen will appear that warns you that the fluid remaining measurement will change as a result of this change Press the Accept key to accept th...

Страница 195: ...ender with the fluid levels Figure 194 below shows a screenshot of the DSM410 with the Custom Calibration option highlighted Custom calibration is necessary for non rectangular tanks and for non stand...

Страница 196: ...first calibration step Enter the first calibration point with an empty tank 0 0 Gallons liters by pressing the Accept key The Current Point highlight will advance to the next point Figure 196 Empty L...

Страница 197: ...will also adjust the tank capacity to the currently indicated level Figure 198 below shows the calibration screen at the last point with the full tank level and thus the tank capacity set to 101 gall...

Страница 198: ...his menu item and then press the Enter key to write the calibration values within the TLA100 and complete the calibration process Figure 200 American Standard Sender Calibration 6 25 4 3 European Stan...

Страница 199: ...he highlighted cursor to Tank Number then press the Enter key to move the cursor over to the tank number value Use the Scroll Up or Scroll Down keys to select the desired tank number Finally press the...

Страница 200: ...erating modes depending on the installation NMEA 2000 the only thing that is connected to the resistive sender is the TLA100 NMEA 2000 Analog Gauge in addition to the TLA100 the resistive sender is al...

Страница 201: ...rsor over the Gauge Resistance to Sender menu item Then press the Enter key to move the highlight over the numerical resistance value Use the Increase and Decrease keys to change the value to the meas...

Страница 202: ...the Gauge Resistance to Sender menu item Then press the Enter key to move the highlight over the numerical resistance value Use the Increase and Decrease keys to change the value to the measured resis...

Страница 203: ...Configuration Screen 6 26 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced configu...

Страница 204: ...ary Switch Status message by pressing the Enter key on the message to be configured Options are Off The fluid level message will not be transmitted On The fluid level message will be transmitted at it...

Страница 205: ...r that warns you that the fluid remaining measurement will change as a result of this change Press the Accept key to accept the change and store the new tank capacity value within the TLM100 or Press...

Страница 206: ...ighted Custom calibration is necessary for non rectangular tanks To perform custom calibration of the tank level sender use the Scroll Up or Scroll Down keys to move the highlighted cursor over the Cu...

Страница 207: ...ibration step Enter the first calibration point with an empty tank 0 0 Gallons liters by pressing the Accept key The Current Point highlight will advance to the next point Figure 214 Empty Level Calib...

Страница 208: ...process and will also adjust the tank capacity to the currently indicated level Figure 216 below shows the calibration screen at the last point with the full tank level and thus the tank capacity set...

Страница 209: ...d you know the capacity of the tank you can easily calibrate the sender by using the Rectangular Tank menu item Figure 218 below shows this option highlighted Use the Scroll Up or Scroll Down keys to...

Страница 210: ...stance used in the data message This can be set from 0 to 15 6 26 6 Tank Type This is set to the type of fluid in the tank Values are Fuel Fresh Water Waste Water Live Well Oil Black Water Reserved 1...

Страница 211: ...29 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced configuration is only done at...

Страница 212: ...r key with NMEA2000 PGN Enable Disable menu item selected causes the DSM410 to display the following screen Figure 222 Figure 222 TMP100 NMEA 2000 PGN Enable Disable Screen You can enable or disable t...

Страница 213: ...ature Inside Temperature Live Well Temperature Main Cabin Temperature Outside Temperature Refrigeration Temperature Sea Temperature User Defined Temperature 129 144 Use this when none of the above opt...

Страница 214: ...e Selection Figure 224 USB100 Configuration Screen 6 30 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced us...

Страница 215: ...G Do not select multiple devices of the same type for display This will result in multiple and possibly conflicting readings Figure 226 USB100 Device Selection Screen The NA column of the menu display...

Страница 216: ...SM410 is capable of performing configuration of the VDR100 Vessel Data Recorder This describes the configuration of the Maretron VDR100 firmware version 2 0 0 4 Figure 227 below shows a screenshot of...

Страница 217: ...0 obtains its LAN connection settings from a DHCP server on the local area network When set to Yes the default value the VDR100 will obtain all necessary connection settings IP Address Subnet Mask Def...

Страница 218: ...s parameter 6 31 8 Default DNS This is the IP address of a computer on the Internet that can identify and locate computer systems and resources on the internet In most cases this should not be require...

Страница 219: ...sure sensors on the network 6 32 1 4 Instance Temperature This entry allows you to program the NMEA 2000 device instance for the temperature transmitted in PGN 130312 You usually will not need to modi...

Страница 220: ...d Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key Notice that by default the old Environmental Parameters message PGN 130310 is disabled while the new Env...

Страница 221: ...actory preset can be easily compensated for using the Installation Offset calibration menu item To perform installation offset calibration use the Scroll Up or Scroll Down keys to move the highlighted...

Страница 222: ...Wind Speed If the wind speed is sufficient then a confirmation screen shown in Figure 235 below will appear indicating that a successful installation offset calibration has completed Figure 235 Instal...

Страница 223: ...press the Enter key to move the highlight to the numerical value on the right This is shown in Figure 237 below Use the Increase and Decrease keys to adjust the damping period to the desired value and...

Страница 224: ...nt However the current humidity level may be entered in this screen to re calibrate the WSO100 should this be required Figure 239 Setting the Outside Humidity Use the Increase and Decrease buttons to...

Страница 225: ...Revision 1 7 2 Page 209 Figure 240 Setting the Outside Temperature Use the Increase and Decrease buttons to select the correct temperature and the press the Enter button to store it...

Страница 226: ...n order to set the Anchor Drop position using the display create a screen with an Anchor Watch display In normal operating mode use the Scroll Up and Scroll Down keys to change to the screen containin...

Страница 227: ...42 below Figure 242 Bar Graph Display Example 7 3 Compass Rose Display The compass rose display shows a heading bearing or course parameter on a compass rose display There are two types of compass ros...

Страница 228: ...DSM410 User s Manual Page 212 Revision 1 7 2 Figure 244 Compass Rose North Up Display...

Страница 229: ...Display Example 7 5 Date Time The Date Time display shows a date and time on a single display The format of the date shown can be set using the Units menu please refer to 5 2 7 13 for details on how t...

Страница 230: ...og gauge There is a general gauge format for most types of display and a specialized rudder gauge display A full screen example of a tachometer display can be seen in Figure 247 below Figure 247 Gauge...

Страница 231: ...ected GPS receiver GPS operating mode 2D 3D DGPS Satellite signal strength up to 12 satellites Satellite azimuth and elevation up to 12 satellites Position HDOP Time Date Accuracy of position An examp...

Страница 232: ...the network with an indicator light display that emulates a status light on a control panel The display may be set up in several different configurations Single Indicator Light this creates a single i...

Страница 233: ...ows or 2 rows 2 column indicator light configurations In order to configure the individual indicator lights press the Enter key with the selected type highlighted to display a menu with entries for ea...

Страница 234: ...onnection The default color is red Instance the instance number of the switch bank containing the indicator to be monitored Channel the channel number of the indicator to be monitored Title Sets the t...

Страница 235: ...gure 254 Numeric Display Example The upper left hand corner indicates the parameter being displayed and the center of the screen shows the numeric value for the indicated parameter The bottom right ha...

Страница 236: ...indicated parameter The bottom right hand corner shows the units 7 12Rolling Road The DSM410 supports a Rolling Road or navigation highway display This display repeats transmitted navigation data fro...

Страница 237: ...d are COG SOG ETA and TTG On the navigation highway itself the waypoint name if available is displayed on the upper left and the waypoint number if available is displayed on the upper right The dashed...

Страница 238: ...day The line graph display can show the selected data over a time period of 1 2 3 4 5 6 or 7 days Line graph displays are supported only for barometric pressure Figure 258 Line Graph Display 7 14SMS...

Страница 239: ...ws a time value in an hours and minutes format Figure 260 below shows an example of this type of display Figure 260 Time hh mm Display 7 16Time hh mm ss The Time hm mm ss display shows a time value in...

Страница 240: ...VDR is Recording Please refer to the VDR100 User s Manual for other status that could be displayed on the VDR Status display Figure 262 below shows an example of this type of display Figure 262 VDR St...

Страница 241: ...ather display shows the following information Wind Direction Ground Referenced Wind Speed Ground Referenced Heat Index Wind Chill Outside Temperature Outside Humidity Barometric Pressure Inside Temper...

Страница 242: ...ose appears in Figure 264 below Figure 264 Wind Rose Display 7 20Moon Phase Display The DSM410 supports a moon phase display which shows the current phase of the moon at the current location An exampl...

Страница 243: ...bar graph A screenshot of the trim tab display appears in Figure 267 below Figure 267 Trim Tab Display 7 23Swing Meter Display The DSM410 supports a swing meter display similar to those found on dedic...

Страница 244: ...og gauge with 180 of travel A screenshot of a tank gauge display showing a fuel tank s level appears in Figure 269 below Figure 269 Tank Gauge Display 7 25Watermaker Status The DSM410 supports a water...

Страница 245: ...may be set up in several different configurations Single Indicator Light this creates a single switch breaker 2 rows this creates four rows of single switches breakers 3 rows this creates three rows...

Страница 246: ...in Figure 272 below Figure 272 Selection of an Individual Switch Breaker Figure 273 below shows the configuration menu for each individual switch breaker Figure 273 Configuration of an Individual Swi...

Страница 247: ...breaker which has been configured to refer to the switch bank instance and indicator number of the switch breaker you want to control In normal operating mode use the Scroll Up and Scroll Down keys t...

Страница 248: ...DSM410 User s Manual Page 232 Revision 1 7 2 Figure 274 Favorite Screen Showing Highlighted Switch Breaker...

Страница 249: ...ge is sent back to the Alert Source 8 1 Displaying Active Alerts Active Alerts are overlaid on all the favorite screens Figure 275 Alert Display The number of Alerts with pending operator actions is s...

Страница 250: ...with the highest priority that requires accepting or cancelling is shown at the bottom left of the screen see Figure 275 This Alert may easily be accepted or cancelled without changing screens by pres...

Страница 251: ...t or Cancel the Alert 8 3 Adding an Alert Alerts are created by selecting the parameter to be monitored e g Depth and then selecting the type of Alert e g High Alert Start by going to the Add New Aler...

Страница 252: ...Scroll Down buttons 8 3 2 Alert Type This allows the selection of the type of Alert see paragraph 4 3 1 The options here are Alarm Warning The desired option is selected using the Scroll Up and Scroll...

Страница 253: ...5 Description This is a textual field that will be displayed on the DSM410 and transmitted to Alert Slave devices It is intended to describe the alert e g Fire 8 3 6 Location This is a textual field t...

Страница 254: ...minate any temporary transitions of the input signal above the High Alert Set Point lasting less than 5 seconds from triggering an alert Once the alert is triggered it becomes an active alert An alert...

Страница 255: ...n order for an alert to become active This can be used to prevent false alerts caused by parameter values that briefly have a value that would cause an alert but quickly return to the normal value ran...

Страница 256: ...the Set Delay to 5 seconds will eliminate any temporary transitions of the input signal above the Low Alert Set Point lasting less than 5 seconds from triggering an alert Once the alert is triggered...

Страница 257: ...eing monitored must rise above the Low Alert Clear Point value for longer than the time in this field in order for the alert to become inactive The value is entered as minutes seconds If only one numb...

Страница 258: ...with a valid value for longer than the time in this field in order for the alert to become inactive 8 3 7 4 Trigger Type is On Alert As opposed to high and low alerts that are associated with analog...

Страница 259: ...the alert will be triggered Alert Clear Delay The condition for the parameter being monitored must be not in its error condition for at least the clear delay time before the alert will become cleared...

Страница 260: ...value of 0 00 is entered then the alert will never re trigger Alert Set Delay If the switch being monitored is in the Off state for the amount of time specified in this field the alert will become ac...

Страница 261: ...te other than Tripped for the amount of time specified in this field the alert will become inactive 8 3 7 7 Trigger Type is Outside Radius Alert The Outside Radius Alert is used to signal an alert whe...

Страница 262: ...unciators will begin sounding again for that alert If a value of 0 00 is entered then the alert will never re trigger Alert Set Point If the distance between the current GPS position and the reference...

Страница 263: ...vessel comes within a certain distance or radius of a reference point expressed as a longitude and latitude Figure 291 shows an Inside Radius Alert and associated parameters 8 3 7 8 1 Trigger Configu...

Страница 264: ...ert is useful when the vessel is anchored or moored and the vessel should not drift outside a perimeter and if it does an alert is activated The point of reference can be selected from the current pos...

Страница 265: ...onger than the time specified in the Alert Set Delay field the alert will become active Alert Clear Point The Alert will be cleared when the quality of the GPS fix as reported by the GPS becomes bette...

Страница 266: ...will stop sounding If the condition which caused the alert remains true after the amount of time in this field the alert will return to the Active state and annunciators will begin sounding again for...

Страница 267: ...dically making them useful for signaling watch changes for example every four hours or as a personnel alarm making sure a crew member is at the helm every 15 minutes When a Time Alert with a Repeat In...

Страница 268: ...ne tenth second on one tenth second off beeps followed by one and a half seconds of silence The sequence is repeated This corresponds to the requirements for Temporal 4 alarms T4 CO Fire This is a ser...

Страница 269: ...ose to send a message when the alert is triggered when the alert is cleared or both when the alert is triggered and when the alert is cleared After you select this entry and press Enter the screen cha...

Страница 270: ...sing the Scroll Up and Scroll Down buttons and then pressing the Enter button again 8 3 13 Operating Mode Underway See Section 4 3 4 for a description of Operating Modes For this Alert to be triggered...

Страница 271: ...ns and then pressing the Enter button again 8 4 Deleting an Alert From the Alert Setup Menu select the menu item Delete Alert Figure 299 Deleting an Alert This brings up the list of Alerts managed by...

Страница 272: ...yed Figure 301 Deleting an Alert Confirmation Press the Accept button to delete the Alert or the Cancel button to return to the previous screen without deleting the Alert 8 5 Editing an Alert From the...

Страница 273: ...parameters of the chosen Alert See Section 8 1 for details of these parameters 8 6 Setting the Vessel Operating Mode The Vessel Operating Mode must be set on each DSM410 This is a potentially risky op...

Страница 274: ...Mode selected 8 7 SMS Text Phone Book The display is able to transmit SMS text messages via a Maretron SMS100 SMS Text Module in the event of an alert This menu allows you to program up to eight diff...

Страница 275: ...splay the SMS Text Phone Book as shown in the figure below Figure 306 SMS Text Phone Book Screen To edit a number in the phone book press Scroll Up and Scroll Down until the desired entry is highlight...

Страница 276: ...the phone number and saved it by pressing Enter a second time after the last digit is entered you will then be given the chance to edit the name for the phone number as shown in Figure 308 below The p...

Страница 277: ...screen Once you have created all of the phone book entries you need press the Back key to exit the SMS Text Phone Book screen 8 8 Advanced Configuration The Advanced Parameters of the Alert System may...

Страница 278: ...ptions here are Enable Disable 8 8 2 Flashing Screen As an extra means to gain the operator s attention to an Active Alert the DSM410 may be set up to flash the entire screen between Red for Alarms or...

Страница 279: ...cal cleaners as they may remove paint or markings or may corrode the DSM410 enclosure or seals Do not use any cleaners containing acetone as they will deteriorate the plastic enclosure Ensure that the...

Страница 280: ...to the network is in transmitting a valid data value Data fluctuates between two different values Two devices on the network are transmitting the same data Check the Instance Numbers on all devices tr...

Страница 281: ...age Phase A Frequency Phase A L N Voltage Phase AB L L Voltage Phase B Frequency Phase B L N Voltage Phase BC L L Voltage Phase C Frequency Phase C L N Voltage Phase CA L L Voltage Anchor Watch DC Cur...

Страница 282: ...ndicator Speed Through Water Over Ground Total Log Trip Log Tanks Capacity Level Remaining Temperature Bait Well Battery Engine Coolant Engine Oil Engine Room Exhaust Gas Freezer Heat Index Heating Sy...

Страница 283: ...A 65020 Gen Phase C AC Power N A 65021 Gen Phase C AC Basic Quantities N A 65022 Gen Phase B AC Reactive Power N A 65023 Gen Phase B AC Power N A 65024 Gen Phase B AC Basic Quantities N A 65025 Gen Ph...

Страница 284: ...In View N A 130306 Wind Data N A 130310 Environmental Parameters N A 130311 Environmental Parameters N A 130312 Temperature N A 130313 Humidity N A 130314 Actual Pressure N A 130316 Temperature Exten...

Страница 285: ...nt Environmental Parameter Value IEC 60945 Classification Exposed Degree of Protection IP67 Operating Temperature 20 C to 70 C Storage Temperature 30 C to 80 C Relative Humidity 93 RH 40 C per IEC6094...

Страница 286: ...technical support for Maretron products you can reach us in any of the following ways Telephone 1 866 550 9100 Fax 1 602 861 1777 E mail support maretron com World Wide Web http www maretron com Mail...

Страница 287: ...ng the following diagram as a template for drilling the mounting holes because the printing process may have distorted the template Figure 312 Flush Mounting Template 93mm 3 66 114mm 4 49 114mm 4 49 1...

Страница 288: ...NG WARRANTIES ARE EXPRESSLY IN LIEU OF AND EXCLUDES ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPO...

Страница 289: ...ll shipping and insurance charges Maretron will return the replaced or repaired product with all shipping and handling prepaid except for requests requiring expedited shipping i e overnight shipments...

Отзывы: