Section 7
Refrigeration System
7-47
Recovery/Evacuation Connections
SV1461
CLOSED
SCALE
OPEN
VACUUM PUMP/
RECOVERY UNIT
MANIFOLD SET
HEAD PRESSURE
CONTROL VALVE
OPEN
OPEN
TEE
R
C
B
REMOTE CONDENSER
CHECK VALVE
RECEIVER SERVICE
VALVE (HALF
OPEN)
DRIER
LIQUID LINE
SOLENOID
HARVEST PRESSURE
REGULATING VALVE
HIGH SIDE SERVICE
VALVE
(BACKSEATED)
DISCHARGE LINE
QUICK CONNECT
SCHRAEDER FITTING
CHECK VALVE
LOW SIDE
SERVICE VALVE
(BACKSEATED)
COMPRESSOR
STRAINER
HOT GAS
SOLENOID
VALVES
EXPANSION
VALVE
EVAPORATOR
HEAT EXCHANGER
HARVEST
PRESSURE
SOLENOID
VALVE