![Manitowoc J-1300 Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/manitowoc/j-1300/j-1300_service-manual_700968116.webp)
Section 7
Refrigeration System
7-11
ICE FORMATION PATTERN
Evaporator ice formation pattern analysis is helpful in
ice machine diagnostics.
Analyzing the ice formation pattern alone cannot
diagnose an ice machine malfunction. However,
when this analysis is used along with Manitowoc’s
Refrigeration System Operational Analysis Table, it
can help diagnose an ice machine malfunction.
Improper ice formation can be caused by any number
of problems.
Example: An ice formation that is “extremely thin on
top” could be caused by a hot water supply, a dump
valve leaking water, a faulty float valve, a low
refrigerant charge, etc.
Important
Keep the water curtain in place while checking the
ice formation pattern to ensure no water is lost.
1. Normal Ice Formation
Ice forms across the entire evaporator surface.
At the beginning of the freeze cycle, it may appear
that more ice is forming on the bottom of the
evaporator than on the top. At the end of the freeze
cycle, ice formation on the top will be close to, or just
a bit thinner than, ice formation on the bottom. The
dimples in the cubes at the top of the evaporator may
be more pronounced than those on the bottom. This is
normal.
The ice thickness probe must be set to maintain the
ice bridge thickness at approximately 1/8”. If ice
forms uniformly across the evaporator surface, but
does not reach 1/8” in the proper amount of time, this
is still considered normal.
2. Extremely Thin at Evaporator Outlet
There is no ice, or a considerable lack of ice
formation on the top of the evaporator (tubing outlet).
Examples: No ice at all on the top of the evaporator,
but ice forms on the bottom half of the evaporator.
Or, the ice at the top of the evaporator reaches 1/8” to
initiate a harvest, but the bottom of the evaporator
already has 1/2” to 1” of ice formation.
Extremely Thin Ice Formation
at Evaporator Outlet
SV1576
ICE
ICE
OUTLET
INLET
Содержание J-1300
Страница 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Страница 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Страница 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ......