Section 7
Refrigeration System
7-14
Safety Limit #1
Freeze time exceeds 60 minutes for 3 consecutive freeze cycles.
Possible Cause
Check/Correct
Improper installation
•
See “Installation/Visual Inspection Checklist” on page 7-10
Water system
•
Low water pressure (20 psi min.)
•
High water pressure (80 psi max.)
•
High water temperature (90
°
F/32.2
°
C max.)
•
Clogged water distribution tube
•
Dirty/defective float valve
•
Dirty/defective water dump valve
•
Defective water pump
Electrical system
•
Ice thickness probe out of adjustment
•
Harvest cycle not initiated electrically
•
Contactor not energizing
•
Compressor electrically non-operational
Restricted condenser
air flow (air-cooled models)
•
High inlet air temperature (110
°
F/43.3
°
C max.)
•
Condenser discharge air recirculation
•
Dirty condenser filter
•
Dirty condenser fins
•
Defective fan cycling control
•
Defective fan motor
Restricted condenser water
flow (water-cooled models)
•
Low water pressure (20 psi min.)
•
High water temperature (90
°
F/32.2
°
C max.)
•
Dirty condenser
•
Dirty/defective water regulating valve
•
Water regulating valve out of adjustment
Refrigeration system
•
Non-Manitowoc components
•
Improper refrigerant charge
•
Defective head pressure control (remotes)
•
Defective hot gas valve
•
Defective compressor
•
TXV starving or flooding (check bulb mounting)
•
Non-condensibles in refrigeration system
•
Plugged or restricted high side refrigerant lines or component
NOTE: Because there are many possible external
problems, do not limit your diagnosis to only the
items listed in this chart.
NOTE: This chart reflects the removal of safety limits
#3 and #4 from new style control boards.
Safety Limit Notes
•
A continuos run of 100 harvests automatically erases the safety limit code.
•
The control board will store and indicate only one safety limit - the last one exceeded.
•
If the toggle switch is moved to the
off
position and then back to the
on
position prior to reaching the
100-harvest point, the last safety exceeded will be indicated.
•
If the harvest light did not flash prior to the ice machine restarting, then the ice machine did not stop
because it exceeded a safety.
Содержание J-1300
Страница 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Страница 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Страница 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ......