Section 3
Maintenance
3-9
WATER DUMP VALVE
The water dump valve normally does not require
removal for cleaning. To determine if removal is
necessary:
1.
Locate the water dump valve.
2.
Set the toggle switch to ICE.
3.
While the ice machine is in the freeze mode,
check the dump valve’s clear plastic outlet drain
hose for leakage.
Dump Valve Outlet Drain Hose
A.
If the dump valve is leaking, remove,
disassemble and clean it.
B.
If the dump valve is not leaking, do not
remove it. Instead, follow the “Cleaning
Procedure” on page 3-5.
Follow the procedure below to remove the dump
valve.
WARNING
Disconnect the electric power to the ice machine at
the electric service switch box.
1.
If so equipped, remove the water dump valve
shield from its mounting bracket.
2.
Lift and slide the coil retainer cap from the top of
the coil.
3.
Note the position of the coil assembly on the
valve for assembly later. Leaving the wires
attached, lift the coil assembly off the valve body
and the enclosing tube.
4.
Press down on the plastic nut on the enclosing
tube and rotate it 1/4 turn. Remove the enclosing
tube, plunger, and plastic gasket from the valve
body.
Dump Valve Disassembly
NOTE: At this stage, the water dump valve can easily
be cleaned. If complete removal is desired, continue
with step 5 on the next page.
Important
The plunger and the inside of the enclosing tube
must be completely dry before assembly.
DUMP VALVE
OUTLET
DRAIN HOSE
CAP
SV1456
COIL
ENCLOSING
TUBE
PLUNGER
SPRING STOP
PLASTIC
GASKET
VALVE BODY
SPRING
PLUNGER
Содержание J-1300
Страница 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Страница 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Страница 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ......