![Manitowoc J-1300 Скачать руководство пользователя страница 140](http://html1.mh-extra.com/html/manitowoc/j-1300/j-1300_service-manual_700968140.webp)
Section 7
Refrigeration System
7-35
J450 SERIES REMOTE
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Entering
Condenser
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
10.9-12.8
12.6-14.8
14.1-16.5
80/26.7
11.1-13.1
13.0-15.2
14.5-17.0
1-2.5
90/32.2
11.4-13.4
13.3-15.6
15.0-17.5
100/37.8
12.6-14.8
15.0-17.5
17.0-19.9
110/43.3
14.1-16.5
17.1-19.9
19.0-22.1
1
Times in minutes
24 Hour Ice Production
Air Temp.
Entering
Water Temperature
°°°°
F/
°°°°
C
Condenser
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
480
420
380
80/26.7
470
410
370
90/32.2
460
400
360
100/37.8
420
360
320
110/43.3
380
320
290
1
Based on average ice slab weight of 4.12 - 4.75 lb.
2
Regular cube derate is 7%
3
Ratings with JC0495 condenser, dice or half-dice cubes
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Entering
Condenser
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
-20/-28.9 to
50/10.0
220-245
50-30
175-190
85-100
70/21.1
230-250
50-31
175-190
85-100
80/26.7
240-260
52-32
180-195
85-100
90/32.2
245-270
54-32
185-200
85-100
100/37.8
280-310
57-32
190-205
90-105
110/43.3
290-325
64-39
190-205
95-110
1
Suction pressure drops gradually throughout the freeze cycle
J600 SERIES
SELF-CONTAINED AIR-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Entering
Condenser
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
8.1-9.5
9.5-11.2
10.9-12.8
80/26.7
8.4-9.9
9.7-11.4
11.2-13.1
1-2.5
90/32.2
9.3-10.9
10.6-12.5
12.3-14.4
100/37.8
10.6-12.5
12.3-14.4
14.5-17.0
1
Times in minutes
24 Hour Ice Production
Air Temp.
Entering
Water Temperature
°°°°
F/
°°°°
C
Condenser
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
620
540
480
80/26.7
600
530
470
90/32.2
550
490
430
100/37.8
490
430
370
1
Based on average ice slab weight of 4.12 - 4.75 lb.
2
Regular cube derate is 7%
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Entering
Condenser
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
195-260
42-22
155-180
75-95
70/21.1
220-290
44-22
160-185
85-100
80/26.7
220-305
52-22
160-190
90-110
90/32.2
250-325
52-23
175-195
95-115
100/37.8
280-355
54-30
195-210
95-125
110/43.3
300-385
56-32
200-225
100-135
1
Suction pressure drops gradually throughout the freeze cycle
Содержание J-1300
Страница 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Страница 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Страница 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ......