Section 6
Electrical System
6-7
Harvest Sequence
5. WATER PURGE
The water pump continues to run as the
water dump valve energizes for 45
seconds to purge the water from the water
trough.
The hot gas valve(s) opens at the
beginning of the water purge. Hot
refrigerant gas is diverted into the
evaporator throughout the 45-second
water purge.
After the 45-second water purge, the
water pump and dump valve de-energize.
New style control boards have an
adjustable water purge. This permits a 0
(off), 15, 30 or 45 second water purge.
(Old Style Control Board Shown)
Self-Contained Models
5. Water Purge
(45 Seconds)
Toggle Switch
ICE
Bin Switch
Closed
Control Board Relays
#1
Closed
Water Pump
ON
#2
Closed
Hot Gas Solenoid
ON
#3
Closed
Water Dump Valve
ON
#4
Closed
Contactor Coil
ON
Compressor
ON
Condenser Fan Motor
ON
Safety Controls
(Which could stop ice machine operation)
High Pressure Cut-Out
Closed
Main Fuse (On Control Board)
Closed
Transformer Fuse (On Control Board)
Closed
Thermistor Operation
OK
SV1563
L1
TB35
TB30
TB30
TB30
TB30
SEE SERIAL PLATE FOR VOLTAGE
L2 (N)
TB32
(55)
(61)
(60)
(77)
(80)
(76)
(75)
(98)
(99)
TB3
TB37
(59)
(73)
(74)
(56)
(58)
(57)
HOT GAS
SOLENOID
DUMP
SOLENOID
WATER
PUMP
TERMINATES AT
PIN CONNECTION
CONTACTOR COIL
TRANS.
FUSE
FUSE (7A)
ICE THICKNESS PROBE
DISCHARGE LINE THERMISTOR
3
1
2
4
1D
1C
1B
1A
BIN SWITCH
(62)
(63)
(65)
(64)
(66)
(66)
(67)
(62)
(69)
(68)
HARVEST LIGHT/
SAFETY CODE LIMIT LIGHT
BIN SWITCH LIGHT
ICE
OFF
CLEAN
TOGGLE SWITCH
VIEW FOR WIRING
62
66
69
67
68
HIGH
PRESSURE
CUTOUT
←
←
←
←
INTERNAL
WORKING VIEW
TB35
TB33
TB34
TB30
TB30
(49)
(47)
COMPRESSOR
RUN CAPACITOR
S
R
C
R
R
*OVERLOAD
PTCR
(46)
(45)
(50)
(42)
(48)
(52)
(85)
(86)
(53)
FAN CYCLE
CONTROL
L1
RUN CAPACITOR**
FAN MOTOR
(AIR-COOLED ONLY)
CONTACTOR
CONTACTS
Содержание J-1300
Страница 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Страница 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Страница 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ......