Section 5
Water System Ice Making Sequence of Operation
5-2
HARVEST CYCLE
4.
The water pump and water dump solenoid are
energized for 45 seconds to purge the water from
the water trough.
5.
After the 45-second purge, the water pump and
water dump valve de-energize.
NOTE: New style control boards have an adjustable
water purge in the harvest cycle. This permits a 0
(off), 15, 30 or 45 second purge cycle.
AUTOMATIC SHUT-OFF
There is no water flow during an automatic shut-off.
Water Flow Down the Drain
SV1456
TO DISTRIBUTION TUBE
WATER DUMP VALVE
WATER PUMP
TO DRAIN