Section 7
Refrigeration System
7-36
J600 SERIES WATER-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Around Ice
Machine
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
8.1-9.5
9.2-10.8
11.7-13.7
80/26.7
8.2-9.7
9.4-11.1
12.0-14.1
1-2.5
90/32.2
8.4-9.9
9.6-11.3
12.3-14.4
100/37.8
8.6-10.1
9.8-11.5
12.6-14.8
1
Times in minutes
24 Hour Ice Production
Air Temp.
Around Ice
Water Temperature
°°°°
F/
°°°°
C
Machine
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
620
555
450
80/26.7
610
545
440
90/32.2
600
535
430
100/37.8
590
525
420
1
Based on average ice slab weight of 4.12 - 4.75 lb.
2
Regular cube derate is 7%
Condenser
90/32.2 Air Temperature Around Ice Machine
Water
Water Temperature
°°°°
F/
°°°°
C
Consumption
50/10.0
70/21.1
90/32.2
Gal/24 hours
550
1000
4600
1
Water regulating valve set to maintain 230 PSIG discharge
pressure
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Around Ice
Machine
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
225-235
46-25
140-184
80-102
70/21.1
225-235
46-26
148-184
82-104
80/26.7
225-235
48-26
154-186
86-108
90/32.2
225-240
48-26
154-190
86-108
100/37.8
225-245
50-28
162-194
86-112
110/43.3
225-250
52-28
165-200
86-115
1
Suction pressure drops gradually throughout the freeze cycle
J600 SERIES REMOTE
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Entering
Condenser
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
8.2-9.7
9.9-11.7
12.0-14.1
80/26.7
8.3-9.8
10.0-11.8
12.1-14.2
1-2.5
90/32.2
8.4-9.9
10.2-11.9
12.3-14.4
100/37.8
8.9-10.5
10.9-12.8
12.6-14.8
110/43.3
9.9-11.7
12.0-14.1
14.1-16.5
1
Times in minutes
24 Hour Ice Production
Air Temp.
Entering
Water Temperature
°°°°
F/
°°°°
C
Condenser
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
610
520
440
80/26.7
605
515
435
90/32.2
600
510
430
100/37.8
570
480
420
110/43.3
520
440
380
1
Based on average ice slab weight of 4.12 - 4.75 lb.
2
Regular cube derate is 7%
3
Ratings with JC0895 condenser, dice or half-dice cubes
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Entering
Condenser
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
-20/-28.9 to
50/10.0
220-250
42-26
152-170
75-90
70/21.1
245-260
44-26
155-172
82-94
80/26.7
245-265
46-26
156-174
82-95
90/32.2
250-265
48-26
157-174
84-96
100/37.8
265-295
52-26
158-176
84-98
110/43.3
300-335
52-28
158-176
84-102
1
Suction pressure drops gradually throughout the freeze cycle
Содержание J-1300
Страница 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Страница 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Страница 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ......