Maintenance
3-12
FLOAT VALVE
1.
Turn off the water supply to the ice machine at
the water service valve.
2.
Turn the splash shield counterclockwise one or
two turns.
Float Valve Removal
3.
Pull the float valve forward and off the mounting
bracket.
4.
Disconnect the water inlet tube from the float
valve at the compression fitting.
5.
Remove the filter screen and cap for cleaning.
WATER CURTAIN
1.
Gently flex the curtain in the center and remove it
from the right side.
Water Curtain Removal
2.
Slide the left pin out.
SV1217
WATER INLET
TUBE
SV1213
COMPRESSION
FITTING
FILTER SCREEN
AND CAP
SPLASH
SHIELD