Section 7
Refrigeration System
7-39
J1000 SERIES WATER-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Around Ice
Machine
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
8.8-9.5
10.1-10.9
11.3-12.2
80/26.7
8.9-9.6
10.2-11.0
11.5-12.3
1-2.5
90/32.2
8.9-9.6
10.2-11.0
11.5-12.3
100/37.8
9.0-9.7
10.4-11.1
11.6-12.5
1
Times in minutes
24 Hour Ice Production
Air Temp.
Around Ice
Water Temperature
°°°°
F/
°°°°
C
Machine
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
1080
960
870
80/26.7
1070
950
860
90/32.2
1070
950
860
100/37.8
1060
940
850
1
Based on average ice slab weight of 7.75 - 8.25 lb.
2
Regular cube derate is 7%
Condenser
90/32.2 Air Temperature Around Ice Machine
Water
Water Temperature
°°°°
F/
°°°°
C
Consumption
50/10.0
70/21.1
90/32.2
Gal/24 hours
840
1650
6600
1
Water regulating valve set to maintain 230 PSIG discharge
pressure
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Around Ice
Machine
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
225-235
36-18
160-185
65-85
70/21.1
225-235
38-18
165-185
70-85
80/26.7
225-235
40-18
165-185
70-85
90/32.2
225-235
40-20
165-185
70-85
100/37.8
225-235
40-20
165-185
70-85
110/43.3
225-240
40-20
170-190
75-90
1
Suction pressure drops gradually throughout the freeze cycle
J1000 SERIES REMOTE
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Entering
Condenser
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
9.1-9.8
10.6-11.4
11.8-12.6
80/26.7
9.3-10.0
10.4-11.6
12.0-12.8
1-2.5
90/32.2
9.4-10.2
10.8-11.7
12.1-13.0
100/37.8
10.0-10.8
11.6-12.5
13.0-13.9
110/43.3
10.8-11.6
12.6-13.5
14.2-15.2
1
Times in minutes
24 Hour Ice Production
Air Temp.
Entering
Water Temperature
°°°°
F/
°°°°
C
Condenser
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
1050
920
840
80/26.7
1035
910
830
90/32.2
1020
900
820
100/37.8
970
850
770
110/43.3
910
790
710
1
Based on average ice slab weight of 7.75 - 8.25 lb.
2
Regular cube derate is 7%
3
Ratings with JC1095 condenser, dice or half-dice cubes
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Entering
Condenser
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
-20/-28.9 to
50/10.0
220-250
40-22
180-200
65-90
70/21.1
230-250
40-22
190-200
70-90
80/26.7
240-260
42-22
190-205
70-90
90/32.2
255-265
44-22
195-205
70-90
100/37.8
275-295
44-24
200-210
70-90
110/43.3
280-320
46-26
200-225
75-100
1
Suction pressure drops gradually throughout the freeze cycle
Содержание J-1300
Страница 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Страница 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Страница 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ......