![Manitowoc J-1300 Скачать руководство пользователя страница 147](http://html1.mh-extra.com/html/manitowoc/j-1300/j-1300_service-manual_700968147.webp)
Section 7
Refrigeration System
7-42
J1800 SERIES WATER-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Around Ice
Machine
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
8.8-9.7
10.1-11.1
11.9-13.1
80/26.7
8.9-9.9
10.2-11.2
12.1-13.2
1-2.5
90/32.2
9.0-10.0
10.4-11.4
12.3-13.4
100/37.8
9.2-10.1
10.6-11.6
12.5-13.7
1
Times in minutes
24 Hour Ice Production
Air Temp.
Around Ice
Water Temperature
°°°°
F/
°°°°
C
Machine
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
1840
1640
1420
80/26.7
1820
1620
1400
90/32.2
1800
1600
1380
100/37.8
1780
1580
1360
1
Based on average ice slab weight of 13.19- 14.31 lb.
2
Regular cube derate is 7%
Condenser
90/32.2 Air Temperature Around Ice Machine
Water
Water Temperature
°°°°
F/
°°°°
C
Consumption
50/10.0
70/21.1
90/32.2
Gal/24 hours
1300
2400
7100
1
Water regulating valve set to maintain 240 PSIG discharge
pressure
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Around Ice
Machine
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
235-245
36-20
170-190
65-80
70/21.1
235-245
38-20
170-190
65-80
80/26.7
235-245
40-20
170-190
65-80
90/32.2
235-250
42-22
175-190
65-80
100/37.8
235-255
44-22
175-190
65-80
110/43.3
235-260
46-22
175-190
65-80
1
Suction pressure drops gradually throughout the freeze cycle
J1800 SERIES REMOTE
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Entering
Condenser
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
9.2-10.2
10.6-11.6
11.5-12.6
80/26.7
9.4-10.4
10.8-11.8
11.7-12.9
1-2.5
90/32.2
9.7-10.7
11.2-12.2
12.1-13.2
100/37.8
10.2-11.2
11.9-13.1
13.3-14.6
110/43.3
11.0-12.1
12.9-14.2
14.9-16.3
1
Times in minutes
24 Hour Ice Production
Air Temp.
Entering
Water Temperature
°°°°
F/
°°°°
C
Condenser
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
1770
1570
1470
80/26.7
1735
1545
1435
90/32.2
1700
1500
1400
100/37.8
1620
1420
1280
110/43.3
1520
1320
1160
1
Based on average ice slab weight of 13.19- 14.31 lb.
2
Regular cube derate is 7%
3
Ratings with JC1895 condenser, dice or half-dice cubes
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Entering
Condenser
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
-20/-28.9 to
50/10.0
220-250
38-24
160-180
60-80
70/21.1
250-260
40-24
170-180
60-80
80/26.7
250-270
48-24
175-190
70-90
90/32.2
250-280
50-24
180-200
80-90
100/37.8
270-300
52-28
205-215
80-95
110/43.3
300-350
54-28
205-230
80-100
1
Suction pressure drops gradually throughout the freeze cycle
Содержание J-1300
Страница 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Страница 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Страница 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ......