Section 7
Refrigeration System
7-37
J800 SERIES
SELF-CONTAINED AIR-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Entering
Condenser
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
8.8-10.2
10.3-11.9
11.9-13.6
80/26.7
9.4-10.8
11.0-12.7
12.5-14.4
1-2.5
90/32.2
10.5-11.5
11.6-13.3
13.3-15.2
100/37.8
11.6-13.4
13.6-15.5
15.0-17.2
1
Times in minutes
24 Hour Ice Production
Air Temp.
Entering
Water Temperature
°°°°
F/
°°°°
C
Condenser
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
800
700
620
80/26.7
760
660
590
90/32.2
720
630
560
100/37.8
630
550
500
1
Based on average ice slab weight of 5.75 - 6.50 lb.
2
Regular cube derate is 7%
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Entering
Condenser
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
220-240
31-18
135-180
65-90
70/21.1
220-240
32-18
140-180
70-90
80/26.7
225-260
36-20
140-180
70-95
90/32.2
260-295
38-22
150-200
80-100
100/37.8
300-330
40-24
210-225
80-100
110/43.3
320-360
44-26
210-240
85-120
1
Suction pressure drops gradually throughout the freeze cycle
J800 SERIES WATER-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Freeze Time
Harvest
Around Ice
Machine
Water Temperature
°°°°
F/
°°°°
C
Time
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
8.8-10.2
9.7-11.1
11.9-13.6
80/26.7
9.1-10.5
10.5-11.5
12.3-14.1
1-2.5
90/32.2
9.4-10.8
10.3-11.9
12.8-14.6
100/37.8
9.7-11.1
10.7-12.3
13.3-15.2
1
Times in minutes
24 Hour Ice Production
Air Temp.
Around Ice
Water Temperature
°°°°
F/
°°°°
C
Machine
°°°°
F/
°°°°
C
50/10.0
70/21.1
90/32.2
70/21.1
800
740
620
80/26.7
780
720
600
90/32.2
760
700
580
100/37.8
740
680
560
1
Based on average ice slab weight of 5.75 - 6.50 lb.
2
Regular cube derate is 7%
Condenser
90/32.2 Air Temperature Around Ice Machine
Water
Water Temperature
°°°°
F/
°°°°
C
Consumption
50/10.0
70/21.1
90/32.2
Gal/24 hours
610
1300
6700
1
Water regulating valve set to maintain 230 PSIG discharge
pressure
Operating Pressures
Air Temp.
Freeze Cycle
Harvest Cycle
Around Ice
Machine
°°°°
F/
°°°°
C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
225-235
33-20
160-185
65-85
70/21.1
225-235
34-20
165-185
70-85
80/26.7
225-235
34-20
165-185
70-85
90/32.2
225-235
36-22
165-185
70-85
100/37.8
225-235
36-22
165-185
70-85
110/43.3
225-240
38-24
170-190
75-90
1
Suction pressure drops gradually throughout the freeze cycle
Содержание J-1300
Страница 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Страница 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Страница 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ......