Maintenance
232
Adjusting the Drive Chain Tension
The conveyor belt drive chain is tensioned by undoing the four bolts holding the motor and moving the
motor until the correct tension of 5mm maximum free play at the central point between the pulleys is
achieved.
Adjusting the Reject Devices
Pusher and Retracting Band Rejects
At the reject solenoid valve, adjust the two throttle screws, in conjunction with the reject delay and
dwell times set in the
Rejects Setup
screen, until the required reject timing and speed of operation are
obtained. Both the reject timing and the speed of operation are affected by the air pressure supplied
to the conveyor.
Air Blast Reject
Since this type of reject has no throttles, the only variables that can be adjusted are the reject delay
and dwell times set in the
Rejects Setup
screen. There is no air regulator supplied as standard with
the air blast reject. However, the air supply pressure should be approximately 100psi (6.9 bar).
Software Upgrades
This section provides details for upgrading the IQ
3
+ Metal Detector software.
Pre-requisites for upgrading are a copy of the latest software and help files, and a USB memory stick
which is used to import the latest software, overwriting the existing software installed on the machine.
The following files are required and are available from Loma systems:
■
IQ3_vX.X.X.Xs.hex
– This file contains the operating software for the metal detector. The s in the
file name signifies that it can be installed on systems that only have 2 x 2 MB (4 MB) flash ROMs
fitted in positions U1 and U2 on the Control Board.
■
IQ3_vX.X.X.X.hex
– This file contains the operating software for the metal detector. It can be
installed on systems that have an 8 MB flash ROM fitted in position U5 on the Control Board.
■
IQ3_Plus_vX.X.X.X._zip
- This file contains the GUI software required to operate the touch
screen.
■
Matching HEX and GUI codes.txt
– This file can be opened in Notepad and provides additional
information covering software versions, including a cross reference table between the Hex Code file
versions and their matching GUI Code files to ensure that compatible versions of each file are
installed.
■
Help_vX.X.X.X.zip
– This zipped folder contains a number of language sub-folders which each
contain translated help text files. The set of files used by the software depends on the language
selected in the
Language Setup
screen when setting up the metal detector.
The Xs used in the file names above have been used to substitute the version numbers. So
for example the current GUI software version is IQ3_Plus_v1.9.2.10._zip at the time of
writing this document.
1.
Obtain a copy of the applicable upgrade files for your system from Loma Systems.
2.
Insert a USB memory stick into your PC and copy the following files onto it:
IQ3_vX.X.X.Xs.hex
IQ3_vX.X.X.X.hex
3.
Create a new folder on the USB memory stick called
IQ3_Plus_vX.X.X.X
using the
version numbers on the source file.
Содержание IQ3+
Страница 2: ......
Страница 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 43: ...Installation 33 ...
Страница 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Страница 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...