Logs and Reports
214
■
Problem:
Rej con wind fail - reject confirm window failure. The reject confirmation system has
detected two packs in one reject confirm window.
O
Actions:
1. Check for the possibility of a single pack double triggering the reject confirmation photo-
eye.
2. If two packs were supposed to be rejected than reduce the Reject confirmation window
time.
3. Reduce the reject dwell time.
■
Problem:
Confirm sensor fault - the reject confirm sensor has been blocked for greater than
the Reject confirmation timeout.
O
Actions:
1. Check the sensor for blockage.
2. Check the sensor is working correctly.
■
Problem:
Bin full - the reject bin full sensor has been blocked for longer than 5 seconds and
the transport system has stopped. The bin will need to be emptied before the transport can be
restarted.
O
Action:
If the bin is full:
1. Remove, identify and segregate the product. Once the sensor is unblocked the fault will
automatically clear.
If the bin is not full:
1. Check the Bin full sensor is working correctly.
■
Problem:
Link corrupted - data corruption has occurred between the detector and LomaLink
PC or other controlling device. The operation of the detector is unaffected.
O
Action:
1. Check cabling and link connectors from remote device.
2. Check LomaLink PC or other controlling device for reported errors.
■
Problem:
Link failure - a break in communication between the detector and LomaLink PC/other
controlling device. The operation of the detector is unaffected.
O
Action:
1. Check cabling and link connectors from remote device.
2. Check connections between the detector and LomaLink PC or other controlling device
for loose or broken wiring/connectors.
■
Problem:
PV test timeout - an automated prompt for the PV test has either not been actioned
or completed within the window time set. The transport system may have stopped.
O
Action:
Clear system fault (restart the transport if stopped) and perform a
PV test
.
■
Problem:
PEC obstructed - the product registration photo-eye has remained blocked for
greater than 6 consecutive pack lengths. This fault is only generated if the PEC fault is enabled.
Содержание IQ3+
Страница 2: ......
Страница 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 43: ...Installation 33 ...
Страница 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Страница 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...