The User Interface
164
The door will automatically lock after the time set in the Bin lock timeout field provided in this
screen or after exiting the screen.
■
Mode
The following Mode options are provided for selection:
O
Pulse (only available if a photo-eye is fitted)
If this option is selected, when a contaminated package is detected the reject delay time is
counted down, in order for the package to travel from the photo-eye to the reject device,
where-upon the reject is turned on for a time equal to the reject dwell time. Typically, this
mode of reject would be used for air blast or pusher type rejects for the accurate rejection
of small packages at high speed.
O
Pulse Extension
This option provides the same functionality as the Pulse option, except that the dwell time
is extended if a second contaminated product reaches the reject point before the dwell
time from the first contaminated product has timed out. This could typically be used with an
air blast or retracting band reject device, but not a pusher type device. This reject mode is
always available.
O
Toggle (only available if a photo-eye is fitted)
If this option is selected, when a contaminated package is detected the reject delay time is
counted down, in order for the package to travel to the reject device, where upon the reject
device state is toggled.
The Reject dwell field will not be displayed for configuration in the
Product Settings
screen
as it is not used.
O
Dwell Extension
If this option is selected, when a contaminated product is detected the reject device is
immediately activated, and stays activated for a time equal to the reject dwell time. If a
second reject product is detected before the dwell time has timed out, then the dwell time
is counted down from the beginning again.
The Reject delay field will not be displayed for configuration in the
Product Settings
screen
as it is not used.
O
Reject till accept
If this option is selected, when a contaminated product is detected the delay time is timed
out, at which point the reject device becomes activated. The reject device will then stay
activated until an uncontaminated product reaches the reject point.
The Reject dwell field will appear not be displayed for configuration in the
Product Settings
screen as it is not used.
Tap on the arrow to the right of the field to display the list of Mode options and select the
appropriate one.
■
Relay
The reject relay can be set to be either normally energised or normally de-energised. For
failsafe applications, the relay state should be normally energised so that if there is a fault in the
reject system the relay will drop out causing rejection of all product.
Содержание IQ3+
Страница 2: ......
Страница 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 43: ...Installation 33 ...
Страница 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Страница 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...