The User Interface
158
Measure the product diagonally and enter that length to provide some tolerance and avoid the
generation of false triggers and nuisance error messages; for example where the external
packaging has curled up or packs are presented too close together.
Tap in the Pack length field to display the pop-up numeric keypad screen and enter the pack
length in millimetres.
■
Product type
Tap on the arrow to the right of the field to display a drop down list of options. Then tap on the
best fit option for the type of product being inspected. The available options displayed are
described below.
You should first read the
About Metal Detection
section to gain an understanding of the terms
used below.
O
Unknown
This is the default option and is recommended for selection if you are in any doubt whether
the other options available are more appropriate. In effect you are letting the detector
decide which product type is most suitable to use.
If during the product Learn process no product effect is exhibited, the detector will advise
this and automatically select the Dry option anyway.
O
Dry
Select this option if you are sure that the product will exhibit no product effect. The
detector will then use the pre-set ferrite phase angle rather than learn from the actual
product.
If during the product Learn process a product effect is exhibited, the detector will advise
that the Learn process has failed. You should then set the Product type to Unknown and
repeat the learn process.
O
Metal film
Select this option if the product to be inspected is foil packed.
Note that this option will only appear if the Auto-Frequency option is selected and the Dry
working mode option is not selected in the
Learn Setup
screen.
■
PVS
Select this option if you are using the Performance Validation System to carry out product
testing at specific times and have configured this in the
PVS Setup
screen. You can also access
the
PVS Log
to view the test details.
When the PVS option is selected the following additional items are displayed in the screen:
O
Fe test
Tap in the Fe test field to display the pop-up numeric keypad screen and enter the ferrous
(chrome steel) test piece size in mm to be used for PV testing.
Leave the field blank if this test piece should not be used as part of the PV test.
O
Non-Fe test
Tap in the Non-Fe test field to display the pop-up numeric keypad screen and enter the
non-ferrous (brass) test piece size in mm to be used for PV testing.
Содержание IQ3+
Страница 2: ......
Страница 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 43: ...Installation 33 ...
Страница 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Страница 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...