Logs and Reports
211
Screen Contents
The screen displays a list of errors under the following column headings:
■
Date
– Displays the date that the error occurred.
■
Time
– Displays the time that the error occurred.
■
Problem
– Displays a brief description of the reason why the error has been generated. See
Example problems below.
■
Type
– This column displays the current status of the error:
O
Active
– The error is current and has not been cleared.
O
Event
– The error has been cleared.
O
Passive
– The error has been listed for advice only
The log can hold up to 20 error records. If this number is exceeded and the log has not been sent as
a report, then the oldest record is deleted to provide space for a new record.
Example Problems
Some example run errors problems that may be displayed and suggested remedial actions are listed
below.
■
Problem:
PV test prompt - an automatic programmed PV test prompt has occurred.
O
Action:
Complete a PV Test.
■
Problem:
PEC blocked - the product registration photo-eye has remained blocked for greater
than several (the default is 6) consecutive pack lengths.
O
Actions:
Check the PEC for blockage. Often caused by product backup on the line.
Check the PEC is working correctly.
Check the pack flow length entry is adequate, ensuring an allowance is made for pack
skew.
Ensure correct belt speed is entered.
■
Problem:
Neg delay exten(sion) - reject dwell time setting problem. Variable speed systems
only.
O
Action:
Check the reject delay and dwell time settings.
■
Problem:
Speed too fast - belt speed is greater than the upper limit for filter resistors, coil gap
and belt speed combination. Variable speed systems only.
O
Action:
Decrease belt speed.
■
Problem:
Speed too slow - belt speed is less than the lower limit for filter resistors, coil gap and
belt speed combination. Variable speed systems only.
O
Action:
Increase belt speed.
■
Problem:
Rejects too close - the reject system is still counting out the dwell for a reject when
the next pack to be rejected needs to be rejected.
O
Actions:
Reduce the reject dwell time.
The pack length for product registration photo-eye operation may be too short. Increase
entered length.
Содержание IQ3+
Страница 2: ......
Страница 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 43: ...Installation 33 ...
Страница 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Страница 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...