IF55 ROT CANopen®
4.11 Diagnostic LEDs (Figure 4)
Two LEDs located in the rear side of the converter are designed to show the
operating or fault status of the CANopen® interface.
GREEN
LED
Description
ON
The encoder is in
Operational
state
Single flash
The encoder is in
Stopped
state
Blinking
The encoder is in
Pre-Operational
state
RED
LED
Description
ON
Bus off, the CAN controller is switched off
Double flash
Node guarding error
, see on page 77 ff
Single flash
Max. number of warning errors reached
Blinking
Generic error or
Flash memory error
, see on
page 77 ff
OFF
No error
During initialization, the device carries out a hardware test to check LEDs
operation. Both LEDs light up.