IF55 ROT CANopen®
6507-00 Profile and software version
[Unsigned32, ro]
It shows the version of both the profile and the software.
Version of the profile for encoders = 3.1
Software version = 1.1
Default = 0301 0101h
6508-00 Operating time
[Unsigned32, ro]
This object contains the information on the operating time. The operating time
monitor stores the operating time for the encoder expressed in operating hours.
The operating time is stored in the encoder non-volatile memory as long as the
encoder is power supplied.
This object is currently not used in this encoder.
Default = FFFF FFFFh (not used)
6509-00 Offset value
[Integer32, ro]
As soon as you activate the preset, the current position of the encoder is saved
in this object. The offset value is then used in the preset function in order to
calculate the encoder position value to be transmitted. To zero set the value in
this object you must upload the factory default values (see the
For any further information on the preset function and the meaning and use of
the related objects and commands
Default = 0000 0000h
650A-01 Module identification
[Integer32, ro]
This object contains the manufacturer-specific offset value. This is the
difference between the physical zero position of the encoder (zero set
mechanically) and the zero position set by the manufacturer (zero set via
software).
Default = 0000 0000h
650B-00 Serial number
[Unsigned32, ro]
This object contains the serial number of the converter.
This object is currently not used in this converter.
Default = FFFF FFFFh (not used)