IF55 ROT CANopen®
bit 15 = 0:
Stopped
or
Pre-operational
state;
bit 15 = 1:
Operational
state.
6501-00 Singleturn resolution
[Unsigned32, ro]
WARNING
This object is active only if the bit 2
object is set to “=0”; otherwise it is ignored and the
system uses the custom values (
6001-00 Programmable pulse per revolution
6002-00 Programmable total measuring range
) to calculate the
position information.
Furthermore, if the
object (see on page 60) is set to “1” =
enabled, the scaling function -even if enabled- is ignored and the position
information is outputted as it is.
This object is intended to show the number of physical distinguishable steps
each turn provided by the hardware (physical singleturn resolution). The
physical singleturn resolution of the connected encoder must be set next to the
2200-04 Physical Singleturn Resolution [bits]
2200-04 Physical Singleturn Resolution [bits]
object, the system automatically sets the value in this object accordingly.
If the bit 2
object is set to “=0” the system uses the value in this object (and the value in
the
6502-00 Number of distinguishable revolutions
position information. If the bit 2
object is set to “=1” the system uses the custom values
6001-00 Programmable pulse per revolution
) to calculate the position information.
If you want to set a custom resolution see the
object.
NOTE
Refer to the “7 - Setting-up” section on page 81 for an example of how the
object is to be read.
6502-00 Number of distinguishable revolutions
[Unsigned16, ro]
WARNING
This object is active only if the bit 2
object is set to “=0”; otherwise it is ignored and the
MAN IF55 ROT CB E 1.2.odt
6 - CANopen® interface (DS 406)
72 of 88
Содержание IF55 ROT CB
Страница 87: ...This page intentionally left blank ...