IF55 ROT CANopen®
4.6 Shield connection
Disentangle and shorten the shielding
1
and then bend it over the part
2
; finally
place the ring nut
3
of the connector. Be sure that the shielding
1
is in tight
contact with the ring nut
3
.
4.7 POWER SUPPLY DIP switch (Figure 8)
WARNING
Power supply must be turned off before performing this operation!
The power supply voltage level to be provided to the connected encoder must
be set through the POWER SUPPLY DIP switch located inside the enclosure of
the converter. It must be according to the power supply voltage level required
by the connected SSI encoder. To access the POWER SUPPLY DIP switch refer to
the “4.1 Converter's connection cap (Figure 5)” section on page 25.
Set the POWER SUPPLY DIP switch to UP position to p10Vdc +30Vdc
power supply voltage level to the encoder (default setting); set the POWER
SUPPLY DIP switch to DOWN position to p5Vdc ±5% power supply
voltage level to the encoder.
MAN IF55 ROT CB E 1.2.odt
4 - Electrical connections
29 of 88