IF55 ROT CANopen®
01h: synchronous transmission at each SYNC command;
02h: synchronous transmission every two SYNC commands;
…
FEh: cyclic transmission:
≠
0
“cyclic transmission”: the cycle time is
object;
the PDO message is not sent.
1A00-01 TPDO1 mapping parameter
[Unsigned32, rw]
This object contains the mapping of the PDO the encoder uses to transmit the
position value, according to the DS 406 device profile specifications.
This object describes the content of the PDO by its index, sub-index and length.
The length contains the length of the application object expressed in bits.
31
24 23
16 15
8
7
0
Index
Sub-Index
Length
MSB
LSB
Default = 6004 0020h =
object, the length is 32 bits.
1A01-01 TPDO2 mapping parameter
1A00-01 TPDO1 mapping parameter
object.
Default = 6004 0020h =
object, the length is 32 bits.
1A02-01 TPDO3 mapping parameter
1A00-01 TPDO1 mapping parameter
object.
6008-00 High precision position value
length is 64 bits.
MAN IF55 ROT CB E 1.2.odt