IF55 ROT CANopen®
Limit switch min.
Limit switch max.
They allow to enable (1) / disable (0) the function of the
objects respectively. For further
information see on page 56.
To know whether the
enabled, you can read the bit 12
of the
6001-00 Programmable pulse per revolution
[Unsigned32, rw]
WARNING
This object is active only if the bit 2
object is set to “=1”; otherwise it is ignored and the
system uses the physical values (
and
Number of distinguishable revolutions
) to calculate the position information.
object (see on page 60) is set to “1” =
enabled, the scaling function -even if enabled- is ignored and the position
information is outputted as it is.
This object sets a custom number of distinguishable steps per revolution
(custom singleturn resolution). The value has to be comprised between 1 and
. If you enter an out-of-range value, the
number of steps per revolution is forced to the physical singleturn resolution.
To avoid counting errors, please check that
= integer value.
6001-00 Programmable pulse per revolution
Default = 0001 0000h
Setting the resolution per revolution
6001-00 Programmable pulse per
(2
16
=0001 0000h)
Master
Encoder (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
23
01
60
00
00
00
01
00
Encoder
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
01
60
00
00
00
00
00
MAN IF55 ROT CB E 1.2.odt
6 - CANopen® interface (DS 406)
63 of 88