IF55 ROT CANopen®
The interval between the SYNC commands must be set next to this
, sub 2 object.
WARNING
Following an attempt to set the
Transmission Type
to 0, the value is
accepted but the PDO message is not sent; following an attempt to
change the
Transmission Type
to any other value that is not supported
by the device, an abort message (abort code = 0609 0030h:
Invalid
value for parameter
) is generated.
If the value next to the
≠
0, the PDO
message is sent cyclically and the interval between two messages is the
time set next to the
object = 0, the PDO message is
not sent.
NOTE
Refer to the “7 - Setting-up” section on page 81 for an example of how the
object is to be set.
1802 PDO3 parameters
PDO3 message is used by default for synchronous transmission of the position
value. For more information refer to the “6.6 PDO objects” section on page 44.
01 COB-ID of the PDO3
[Unsigned32, rw]
Bit number
Value Meaning
31 (MSB)
0
PDO exists / is valid
1
PDO does not exist / is not valid
30
0
RTR allowed on this PDO
(not implemented)
1
no RTR allowed on this PDO
29
0
11-bit ID (CAN 2.0A)
1
29-bit ID (CAN 2.0B)
28 … 11
0
if bit 29 = 0
X
if bit 29 = 1: bits 28-11 of 29-bit-COB-ID
10 … 0 (LSB)
X
bits 10-0 of COB-ID
Default = C000 0380h+Node-ID (disable, no RTR)
WARNING
It is mandatory to set the bit 30 of COB-ID to 1 (value 0 is not allowed).
This means that “No RTR is allowed on the PDO”.
At power on, this object is forced to the default value.