IF55 ROT CANopen®
1801 PDO2 parameters
PDO2 message is used by default for synchronous transmission of the position
value. For more information refer to the “6.6 PDO objects” section on page 44.
01 COB-ID of the PDO2
[Unsigned32, rw]
Bit number
Value Meaning
31 (MSB)
0
PDO exists / is valid
1
PDO does not exist / is not valid
30
0
RTR allowed on this PDO
(not implemented)
1
no RTR allowed on this PDO
29
0
11-bit ID (CAN 2.0A)
1
29-bit ID (CAN 2.0B)
28 … 11
0
if bit 29 = 0
X
if bit 29 = 1: bits 28-11 of 29-bit-COB-ID
10 … 0 (LSB)
X
bits 10-0 of COB-ID
Default = 4000 0280h+Node-ID (no RTR, COB-ID)
WARNING
It is mandatory to set the bit 30 of COB-ID to 1 (value 0 is not allowed).
This means that “No RTR is allowed on the PDO”.
At power on, this object is forced to the default value.
02 Transmission type
[Unsigned8, rw]
Transmission type
PDO transmission
00h (0)
Acyclic, synchronous
not implemented
01h … F0h (1 … 240)
Cyclic, synchronous
implemented
F1h … FBh (241 … 251)
not implemented - reserved
FCh (252)
Synchronous, RTR only
not implemented
FDh (253)
Asynchronous, RTR only
not implemented
FEh (254)
Asynchronous,
manufacturer specific
implemented
FFh (255)
Asynchronous, device
profile specific
not implemented
Default = 01h (synchronous transmission at each SYNC command)
The position value is transmitted after the set number of SYNC
commands.
MAN IF55 ROT CB E 1.2.odt
6 - CANopen® interface (DS 406)
52 of 88
Содержание IF55 ROT CB
Страница 87: ...This page intentionally left blank ...