IF55 ROT CANopen®
7.4 Setting the resolution per revolution
6001-00 Programmable pulse per revolution
(2
16
=0001 0000h)
Master
Slave (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
23
01
60
00
00
00
01
00
Slave
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
01
60
00
00
00
00
00
7.5 Setting the total resolution
6002-00 Programmable total measuring range
(2
30
=4000 0000h)
Master
Slave (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
23
02
60
00
00
00
00
40
Slave
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
02
60
00
00
00
00
00
7.6 Setting the Operating parameters
: 0 = CW,
: 1 = enabled,
: 0 = disabled)
Master
Slave (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
2B
00
60
00
04
00
-
-
Slave
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
00
60
00
00
00
-
-
7.7 Setting the Preset value
Master
Slave (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
23
03
60
00
E8
03
00
00
Slave
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
03
60
00
00
00
00
00
MAN IF55 ROT CB E 1.2.odt
7 - Setting-up
82 of 88
Содержание IF55 ROT CB
Страница 87: ...This page intentionally left blank ...