IF55 ROT CANopen®
1005-00 COB_ID SYNC message
[Unsigned32, rw]
This object indicates the configured COB-ID of the synchronisation object
(SYNC). Further, it defines whether the CANopen device generates the SYNC.
Default = 0000 0080h (CANopen device generates SYNC message)
1008-00 Manufacturer device name
[String, ro]
It shows the name of the device (manufacturer).
Default = “IF55ROT_CB”
1009-00 Manufacturer hardware version
[String, ro]
It shows the hardware version of the device.
Default = device dependent
100A-00 Manufacturer software version
[String, ro]
It shows the software version of the device.
Default = device dependent
100C-00 Guard time
[Unsigned16, rw]
It allows to set the Guard time expressed in milliseconds (msec).
The
object is used in the “Node guarding protocol”
controlled by the Master. For more details see the “6.11 Node guarding protocol”
section on page 78.
Default = 0000h
100D-00 Life time factor
object is used in the “Node guarding protocol”
controlled by the Master. For more details see the “6.11 Node guarding protocol”
section on page 78.
Default = 00h
MAN IF55 ROT CB E 1.2.odt
6 - CANopen® interface (DS 406)
48 of 88
Содержание IF55 ROT CB
Страница 87: ...This page intentionally left blank ...